Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFloral scents affect reproductive success in fly-pollinated Alocasia odora (Araceae)    Next AbstractComparison of observed and estimated concentrations of volatile organic compounds using a Gaussian dispersion model in the vicinity of factories: an estimation approach to determine annual average concentrations and human health risks »

J Chromatogr A


Title:A method for measuring semi- and non-volatile organic halogens by combustion ion chromatography
Author(s):Miyake Y; Kato M; Urano K;
Address:"National Institute of Advance Industrial Science and Technology, Onogawa 16-1, Tsukuba, Ibaraki, Japan. y-miyake@aist.go.jp"
Journal Title:J Chromatogr A
Year:2007
Volume:20061115
Issue:1
Page Number:63 - 69
DOI: 10.1016/j.chroma.2006.10.078
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"Recent studies have shown that various semi- and non-volatile organohalogen compounds are ubiquitous in the environment: these include halogenated dioxins including chlorinated dioxins, other persistent organic pollutants (POPs), brominated flame retardants (BFRs), and perfluorooctane sulfonate (PFOS). However, monitoring and assessment of these compounds by the analyses of individual compounds and their isomers is onerous because of their low environmental concentrations and large number of compounds. In this study, we have developed a new method that is capable of screening and monitoring an array of organohalogen compounds efficiently by combustion ion chromatography (CIC) - the new analyzer that serially connects combustion furnace and ion chromatograph. Analyzer performance was evaluated in terms of its applicability, reproducibility, and sensitivity as limit of detection (LOD). Recoveries of organochlorine, organobromine, and organoiodine compounds by the CIC were between 97 and 105%; those of organofluorine compounds were from 86 to 91%. In all cases, the relative standard deviation of five analyses was 4% or smaller. The analyzer would exhibit good sensitivity for various environmental matrices (e.g., 2.8-31ng-X/g-soil, 1.4-16ng-X/L-water, and 9.2-100ng-X/m3N-gas). The method is fast and can provide information regarding the occurrence of organohalogen compounds within 1 or 2 days after sampling. Applicability of the new method for the assessment of contamination in flue gas and fly ash was also demonstrated. Our results show that the method is efficient to investigate emission sources and areas contaminated by organohalogen compounds"
Keywords:"Chromatography/instrumentation/*methods Hydrocarbons, Brominated/analysis/chemistry Hydrocarbons, Chlorinated/analysis/chemistry Hydrocarbons, Halogenated/*analysis/chemistry Hydrocarbons, Iodinated/analysis/chemistry Reproducibility of Results Volatiliza;"
Notes:"MedlineMiyake, Yuichi Kato, Mika Urano, Kohei eng Netherlands 2006/11/18 J Chromatogr A. 2007 Jan 12; 1139(1):63-9. doi: 10.1016/j.chroma.2006.10.078. Epub 2006 Nov 15"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024