Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractImpaired male sexual behavior in activin receptor type II knockout mice    Next AbstractAnti-Inflammatory Activity of Oligomeric Proanthocyanidins Via Inhibition of NF-kappaB and MAPK in LPS-Stimulated MAC-T Cells »

J Environ Sci (China)


Title:Determination of Vocs in groundwater at an industrial contamination site using a homemade low-density polyethylene passive diffusion sampler
Author(s):Ma X; Tan Z; Pang L; Liu J;
Address:"State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China"
Journal Title:J Environ Sci (China)
Year:2013
Volume:25
Issue:11
Page Number:2338 - 2343
DOI: 10.1016/s1001-0742(12)60322-2
ISSN/ISBN:1001-0742 (Print) 1001-0742 (Linking)
Abstract:"A home-made inexpensive passive diffusion bag (PDB) sampler, prepared by filling deionized water in low-density polyethylene (LDPE) tubes, was evaluated for volatile organic compounds (VOC) sampling in groundwater at industrial contamination sites. Impacts of environmentally relevant conditions on the sampling equilibration time and partitioning of VOCs between the sampler and the water sample were investigated. Sample salinity, agitation and temperature can influence the equilibration time, but generally sampling equilibration was obtained in 14 days under real field sampling of VOCs in groundwater. Both laboratory study and field testing in a contaminated site showed that the VOC concentrations in the developed sampler were equal to those in the water samples at equilibrium. Coupled with a purge and trap concentrator-gas chromatograph-mass spectrometer (P&T-GC-MS), the developed PDB sampler provided a low-cost sampling device for routine monitoring of VOCs in groundwater in wells, with LODs in the range of 2.9-10 microg/L. The proposed PDB was applied to determine VOCs in groundwater at an industrial contamination site, and the present results agreed well with those determined using conventional pump-and-sample monitoring. All the studied 13 VOCs were tested in the four wells in the industrial contamination sites, with their concentrations in the range of 12-73660 microg/L. In addition, while benzene and toluene were heavily contaminated up to a maximum concentration of 74000 tg/L and 6000 microg/L, respectively, 1,2,3-trichlorobenzene and bromobenzene had relatively low contamination levels (below 25 microg/L)"
Keywords:"*Diffusion Environmental Monitoring/instrumentation/methods Groundwater/*chemistry Industrial Waste/*analysis *Polyethylene Volatile Organic Compounds/*chemistry Water Pollutants, Chemical/*chemistry;"
Notes:"MedlineMa, Xu Tan, Zhiqiang Pang, Long Liu, Jingfu eng Research Support, Non-U.S. Gov't Netherlands 2014/02/21 J Environ Sci (China). 2013 Nov 1; 25(11):2338-43. doi: 10.1016/s1001-0742(12)60322-2"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024