Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEvaluation of the use of bioethanol fuelled buses based on ambient air pollution screening and on-road measurements    Next AbstractAnaerobic treatment of natural tannin extracts in UASB reactors »

J Chromatogr Sci


Title:Determination of volatile priority pollutants in water by purge and trap and capillary column gas chromatography/mass spectrometry
Author(s):Lopez-Avila V; Wood R; Flanagan M; Scott R;
Address:
Journal Title:J Chromatogr Sci
Year:1987
Volume:25
Issue:7
Page Number:286 - 291
DOI: 10.1093/chromsci/25.7.286
ISSN/ISBN:0021-9665 (Print) 0021-9665 (Linking)
Abstract:"Two wide-bore capillary columns are evaluated for their applicability to the purge-and-trap technique and GC/MS analysis of 34 volatile organics. Neither column is able to completely resolve all 34 compounds, as is also typical of the packed column; however, the analysis is faster than with the packed column (18 to 21 min compared to 30 min), and the column effluent is introduced directly into the mass spectrometer without requiring an open-split interface. Method precision, as assessed from the instrument response at a concentration of 50 micrograms/L per component, is better than +/- 5% for 41% of the compounds using the VOCOL column (diphenyl dimethyl polysiloxane with crosslinking moieties) and for 53% of the compounds using the 007 column (95% methyl 5% phenyl silicone). The instrument response is linear from 20 to 200 micrograms/L for most compounds, and the amounts loaded to either column without serious distortion of the peak shape or resolution can be as high as 5 micrograms per component. Because the VOCOL column resolved more compounds than the 007 column within approximately the same analysis time, this column is further tested for performance with groundwater samples"
Keywords:"Gas Chromatography-Mass Spectrometry United States United States Environmental Protection Agency Water Pollutants/*analysis Water Pollutants, Chemical/*analysis Water Supply/analysis;"
Notes:"MedlineLopez-Avila, V Wood, R Flanagan, M Scott, R eng 1987/07/01 J Chromatogr Sci. 1987 Jul; 25(7):286-91. doi: 10.1093/chromsci/25.7.286"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024