Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Effects of Lysobacter antibioticus HS124, an effective biocontrol agent against Fusarium graminearum, on crown rot disease and growth promotion of wheat"    Next AbstractDetermination of volatile organic compounds (VOCs) levels from various smoking cessation aids by using gas chromatography-mass spectrometry methodology »

Sensors (Basel)


Title:Functional Microfiber Nonwoven Fabric with Copper Ion-Immobilized Polymer Brush for Detection and Adsorption of Acetone Gas
Author(s):Kim YY; Uezu K;
Address:"Graduate School of Environmental Engineering, The University of Kitakyushu, 1-1 Hibikino, Kitakyushu 808-0135, Japan. Faculty of Environmental Engineering, The University of Kitakyushu, 1-1 Hibikino, Kitakyushu 808-0135, Japan"
Journal Title:Sensors (Basel)
Year:2021
Volume:20211223
Issue:1
Page Number: -
DOI: 10.3390/s22010091
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"The detection and removal of volatile organic compounds (VOCs) are emerging as an important problem in modern society. In this study, we attempted to develop a new material capable of detecting or adsorbing VOCs by introducing a new functional group and immobilizing metal ions into a microfiber nonwoven fabric (MNWF) made through radiation-induced graft polymerization. The suitable metal complex was selected according to the data in 'Cambridge Crystallographic Data Center (CCDC)'. 4-picolylamine (4-AMP), designated as a ligand through the metal complex data of CCDC, was introduced at an average mole conversion rate of 63%, and copper ions were immobilized at 0.51 mmol/g to the maximum. It was confirmed that degree of grafting (dg) 170% 4-AMP-Cu MNWF, where copper ions are immobilized, can adsorb up to 50% of acetone gas at about 50 ppm, 0.04 mmol/g- 4-AMP-Cu-MNWF, at room temperature and at a ratio of copper ion to adsorbed acetone of 1:10"
Keywords:4-picolylamine VOCs acetone coordination bonding copper ions microfiber nonwoven fabric radiation-induced graft polymerization;
Notes:"PubMed-not-MEDLINEKim, Yung-Yoon Uezu, Kazuya eng Switzerland 2022/01/12 Sensors (Basel). 2021 Dec 23; 22(1):91. doi: 10.3390/s22010091"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-06-2024