Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDiscrimination of bile acids by the rainbow trout olfactory system: evidence as potential pheromone    Next AbstractEffect of the type of oil on the evolution of volatile compounds of taralli during storage »

Anal Chem


Title:Application of low-temperature glassy carbon-coated macrofibers for solid-phase microextraction analysis of simulated breath volatiles
Author(s):Giardina M; Olesik SV;
Address:"Department of Chemistry, The Ohio State University, 100 West 18th Avenue, Columbus, Ohio 43210, USA"
Journal Title:Anal Chem
Year:2003
Volume:75
Issue:7
Page Number:1604 - 1614
DOI: 10.1021/ac025984k
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"With increasing interest in the detection of disease-related volatile organic compounds (VOCs) found in human breath, breath analysis could prove to be a very useful diagnostic tool, especially for the early detection of lung cancer. Solid-phase microextraction (SPME) is a technique well suited for breath analysis and has been applied to studying VOCs in the nanomolar concentration range. However, many compounds of interest in human breath are excreted at picomolar concentrations and may be unsuitable for analysis using conventional SPME sorbent phases. To extend the concentration range of conventional SPME, a novel 4-cm-long, low-temperature glassy carbon (LTGC) macrofiber was developed. The LTGC SPME macrofibers were used to extract five lung cancer-related VOCs (2-methylheptane, styrene, propylbenzene, decane, undecane) at conditions simulating human breath, and they were analyzed via gas chromatography/mass spectrometry. Results show that detection limits are lower using the SPME macrofibers compared to a conventional SPME fiber, in the low- to sub-picomolar range for the compounds of interest, which should be adequate for the analysis of these compounds in human breath. Also, the LTGC SPME macrofibers demonstrate significantly greater extraction efficiencies, sensitivity, and peak identification accuracy compared to that of commercial PDMS/DVB fibers without excessive chromatographic peak broadening. The use of SPME macrofibers broadens the potential range of application of SPME where the rapid extraction of very low levels of volatile compounds is required"
Keywords:Alkanes/analysis Benzene Derivatives/analysis Biomarkers/analysis Breath Tests/*instrumentation/*methods Carbon Gas Chromatography-Mass Spectrometry Glass Heptanes/analysis Humans Lung Neoplasms/*diagnosis Microchemistry/*instrumentation/*methods Reproduc;
Notes:"MedlineGiardina, Matthew Olesik, Susan V eng Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. 2003/04/23 Anal Chem. 2003 Apr 1; 75(7):1604-14. doi: 10.1021/ac025984k"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024