Anal Chem


Title:Development of an automated cylindrical ion trap mass spectrometer for the determination of atmospheric volatile organic compounds
Author(s):Edwards GD; Shepson PB; Grossenbacher JW; Wells JM; Patterson GE; Barket DJ; Pressley S; Karl T; Apel E;
Address:"Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA. gdedwards@eiu.edu"
Journal Title:Anal Chem
Year:2007
Volume:20070602
Issue:13
Page Number:5040 - 5050
DOI: 10.1021/ac0703597
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"Volatile organic compounds released from the biosphere are known to have a large impact on atmospheric chemistry. Field instruments for the detection of these trace gases are often limited by the lack of instrument portability and the inability to distinguish compounds of interest from background or other interfering compounds. We have developed an automated sampling and preconcentration system, coupled to a lightweight, low-power cylindrical ion trap mass spectrometer. The instrument was evaluated by measuring isoprene concentrations during a field campaign at the University of Michigan Biological Station PROPHET lab. Isoprene was preconcentrated by sampling directly into a short capillary column precooled without the aid of cryogens. The capillary column was then rapidly heated by moving the column to a preheated region to obtain fast separation of isoprene from other components, followed by detection with a cylindrical ion trap. This combination yielded a detection limit of approximately 80 ppt (parts per trillion) for isoprene with a measurement frequency of one sample every 11 min. The data obtained by the automated sampling and preconcentration system during the PROPHET 2005 campaign were compared to those of other field instruments measuring isoprene at this site in an intercomparison exercise. The intercomparisons suggest the new inlet system, when coupled with this ion trap detector, provides a viable field instrument for the fast, precise, and quantitative determination of isoprene and other trace gases over a variety of atmospheric conditions"
Keywords:Air Pollutants/*analysis *Automation Butadienes/analysis Hemiterpenes/analysis Humidity Mass Spectrometry/instrumentation/*methods Organic Chemicals/*analysis Pentanes/analysis Time Factors Volatilization;
Notes:"MedlineEdwards, Gavin D Shepson, P B Grossenbacher, J W Wells, J M Patterson, G E Barket, D J Jr Pressley, S Karl, T Apel, E eng Research Support, Non-U.S. Gov't 2007/06/05 Anal Chem. 2007 Jul 1; 79(13):5040-50. doi: 10.1021/ac0703597. Epub 2007 Jun 2"

 