« Previous AbstractTemporally resolved thermal desorption of volatile organics from nanoporous silica preconcentrator    Next AbstractQuorum sensing and the regulation of virulence gene expression in pathogenic bacteria »

J Breath Res


Title:Standardization of the collection of exhaled breath condensate and exhaled breath aerosol using a feedback regulated sampling device
Author(s):Winters BR; Pleil JD; Angrish MM; Stiegel MA; Risby TH; Madden MC;
Address:"Curriculum in Toxicology, University of North Carolina, Chapel Hill, NC, United States of America"
Journal Title:J Breath Res
Year:2017
Volume:20171101
Issue:4
Page Number:47107 -
DOI: 10.1088/1752-7163/aa8bbc
ISSN/ISBN:1752-7163 (Electronic) 1752-7155 (Print) 1752-7155 (Linking)
Abstract:"Exhaled breath condensate (EBC) and associated exhaled breath aerosols (EBA) are valuable non-invasive biological media used for the quantification of biomarkers. EBC contains exhaled water vapor, soluble gas-phase (polar) organic compounds, ionic species, plus other species including semi- and non-volatile organic compounds, proteins, cell fragments, DNA, dissolved inorganic compounds, ions, and microbiota (bacteria and viruses) dissolved in the co-collected EBA. EBC is collected from subjects who breathe 'normally' through a chilled tube assembly for approximately 10 min and is then harvested into small vials for analysis. Aerosol filters without the chilled tube assembly are also used to separately collect EBA. Unlike typical gas-phase breath samples used for environmental and clinical applications, the constituents of EBC and EBA are not easily characterized by total volume or carbon dioxide (CO(2)) concentration, because the gas-phase is vented. Furthermore, EBC and associated EBA are greatly affected by breathing protocol, more specifically, depth of inhalation and expelled breath velocity. We have tested a new instrument developed by Loccioni Gruppa Humancare (Ancona, Italy) for implementation of EBC collection from human subjects to assess EBC collection parameters. The instrument is the first EBC collection device that provides instantaneous visual feedback to the subjects to control breathing patterns. In this report we describe the operation of the instrument, and present an overview of performance and analytical applications"
Keywords:Adult Aerosols/*analysis Biomarkers/analysis Breath Tests/*instrumentation/*methods *Exhalation *Feedback Humans Hydrogen-Ion Concentration Reference Standards;
Notes:"MedlineWinters, Brett R Pleil, Joachim D Angrish, Michelle M Stiegel, Matthew A Risby, Terence H Madden, Michael C eng EPA999999/Intramural EPA/ T32 ES007126/ES/NIEHS NIH HHS/ England 2017/09/13 J Breath Res. 2017 Nov 1; 11(4):047107. doi: 10.1088/1752-7163/aa8bbc"

 