Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile fatty acids in vaginal secretions: human pheromones?    Next AbstractPheromone-based mating disruption of Planococcus ficus (Hemiptera: Pseudococcidae) in California vineyards »

J Breath Res


Title:The use of a portable breath analysis device in monitoring type 1 diabetes patients in a hypoglycaemic clamp: validation with SIFT-MS data
Author(s):Walton C; Patel M; Pitts D; Knight P; Hoashi S; Evans M; Turner C;
Address:"Cranfield University, Cranfield, Bedfordshire, MK43 0AL, UK"
Journal Title:J Breath Res
Year:2014
Volume:20140904
Issue:3
Page Number:37108 -
DOI: 10.1088/1752-7155/8/3/037108
ISSN/ISBN:1752-7163 (Electronic) 1752-7155 (Linking)
Abstract:"Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor the blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor during hypoglycaemic glucose clamps and compare that with the use of SIFT-MS described in previously published work on the same set of patients. Outputs from both devices have been correlated with the concentration of blood glucose in eight volunteers suffering from type 1 diabetes mellitus. The results demonstrate that acetone as measured by SIFT-MS and the sensor output from the breath sensing device both correlate linearly with blood glucose; however, the sensor response and acetone concentrations differ greatly between patients with the same blood glucose. It is therefore unlikely that breath analysis can entirely replace blood glucose testing"
Keywords:"Acetone/analysis Blood Glucose/analysis Breath Tests/*instrumentation/*methods Calibration Diabetes Mellitus, Type 1/*diagnosis Exhalation Glucose Clamp Technique/*instrumentation Humans Ions Mass Spectrometry/*instrumentation Middle Aged Monitoring, Ambu;"
Notes:"MedlineWalton, C Patel, M Pitts, D Knight, P Hoashi, S Evans, M Turner, C eng Wellcome Trust/United Kingdom Clinical Trial Research Support, Non-U.S. Gov't England 2014/09/06 J Breath Res. 2014 Sep; 8(3):037108. doi: 10.1088/1752-7155/8/3/037108. Epub 2014 Sep 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024