Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSustainable Drying and Torrefaction Processes of Miscanthus for Use as a Pelletized Solid Biofuel and Biocarbon-Carrier for Fertilizers    Next AbstractOnline breath gas analysis in unrestrained mice by hs-PTR-MS »

Anal Chim Acta


Title:Re-evaluation of effective carbon number (ECN) approach to predict response factors of 'compounds lacking authentic standards or surrogates' (CLASS) by thermal desorption analysis with GC-MS
Author(s):Szulejko JE; Kim KH;
Address:"Department of Civil and Environmental Engineering, Hanyang University, Seongdong-Gu, 222 Wangsimni-Ro, Seoul 133-791, South Korea. Department of Civil and Environmental Engineering, Hanyang University, Seongdong-Gu, 222 Wangsimni-Ro, Seoul 133-791, South Korea. Electronic address: kkim61@hanyang.ac.kr"
Journal Title:Anal Chim Acta
Year:2014
Volume:20140823
Issue:
Page Number:14 - 22
DOI: 10.1016/j.aca.2014.08.033
ISSN/ISBN:1873-4324 (Electronic) 0003-2670 (Linking)
Abstract:"In our recent study, we experimentally demonstrated the feasibility of an effective carbon number (ECN) approach for the prediction of the response factor (RF) values of 'compounds lacking authentic standards or surrogates' (CLASS) using a certified 54-mix containing 38 halogenated analytes as a pseudo-unknown. Although our recent analysis performed well in terms of RF predictive power for a 25-component learning set (for both Q-MS and TOF-MS detection), large physically unrealistic negative ECN and carbon number equivalent (CNE) values were noted for TOF-MS detection, e.g., ECN (acetic acid)=-16.96. Hence, to further improve the ECN-based quantitation procedure of CLASS, we re-challenged RF vs. ECN linear regression analysis with additional descriptors (i.e., Cl, Br, CC, and a group ECN offset (Ok)) using the 1-point RF values. With an Ok, all compound classes, e.g., halo-alkanes/-alkenes and aromatics can now be fitted to yield consistently positive set of ECN values for most analytes (e.g., 3 outliers out of 29, Q-MS detection). In this way, we were able to further refine our approach so that the absolute percentage difference (PD)+/-standard deviation (SD) between mass detected vs. mass loaded is reduced from 39.0+/-34.1% (previous work) to 13.1+/-12.0% (this work) for 29 C1C4 halocarbons (Q-MS detector)"
Keywords:Carbon/*chemistry Feasibility Studies Gas Chromatography-Mass Spectrometry/*methods/standards Halogenation Reference Standards Temperature Volatile Organic Compounds/*analysis/*chemistry Carbon number Effective carbon number Gas chromatography/mass spectr;
Notes:"MedlineSzulejko, Jan E Kim, Ki-Hyun eng Research Support, Non-U.S. Gov't Netherlands 2014/12/03 Anal Chim Acta. 2014 Dec 3; 851:14-22. doi: 10.1016/j.aca.2014.08.033. Epub 2014 Aug 23"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024