Indoor Air


Title:"Contaminant levels, source strengths, and ventilation rates in California retail stores"
Author(s):Chan WR; Cohn S; Sidheswaran M; Sullivan DP; Fisk WJ;
Address:"Indoor Environment Group, Lawrence Berkeley National Laboratory, Berkeley, CA, USA"
Journal Title:Indoor Air
Year:2015
Volume:20140924
Issue:4
Page Number:381 - 392
DOI: 10.1111/ina.12152
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"This field study measured ventilation rates and indoor air quality in 21 visits to retail stores in California. Three types of stores, such as grocery, furniture/hardware stores, and apparel, were sampled. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California's Title 24 Standard in all but one store. Concentrations of volatile organic compounds (VOCs), ozone, and carbon dioxide measured indoors and outdoors were analyzed. Even though there was adequate ventilation according to standard, concentrations of formaldehyde and acetaldehyde exceeded the most stringent chronic health guidelines in many of the sampled stores. The whole-building emission rates of VOCs were estimated from the measured ventilation rates and the concentrations measured indoor and outdoor. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California's stringent formaldehyde reference level. Given the high costs of providing ventilation, effective source control is an attractive alternative. PRACTICAL IMPLICATIONS: Field measurements suggest that California retail stores were well ventilated relative to the minimum ventilation rate requirement specified in the Building Energy Efficiency Standards Title 24. Concentrations of formaldehyde found in retail stores were low relative to levels found in homes but exceeded the most stringent chronic health guideline. Looking ahead, California is mandating zero energy commercial buildings by 2030. To reduce the energy use from building ventilation while maintaining or even lowering formaldehyde in retail stores, effective formaldehyde source control measures are vitally important"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*statistics & numerical data California Carbon Dioxide/analysis Commerce Ozone/analysis Ventilation/standards/*statistics & numerical data Volatile Organic Compounds/*analysis Building energy efficiency stand;"
Notes:"MedlineChan, W R Cohn, S Sidheswaran, M Sullivan, D P Fisk, W J eng Research Support, U.S. Gov't, Non-P.H.S. England 2014/08/27 Indoor Air. 2015 Aug; 25(4):381-92. doi: 10.1111/ina.12152. Epub 2014 Sep 24"

 