Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOn-line breath analysis with PTR-TOF    Next AbstractTowards standardization in the analysis of breath gas volatiles »

J Breath Res


Title:Proton transfer reaction-mass spectrometry applications in medical research
Author(s):Herbig J; Amann A;
Address:
Journal Title:J Breath Res
Year:2009
Volume:20090609
Issue:2
Page Number:20201 -
DOI: 10.1088/1752-7163/3/2/020201
ISSN/ISBN:1752-7163 (Electronic) 1752-7155 (Linking)
Abstract:"Gathering information about a subject's physiological and pathophysiological condition from the ;smell' of breath is an idea that dates back to antiquity. This intriguing concept of non-invasive diagnosis has been revitalized by ;exhaled breath analysis' in recent decades. A main driving force was the development of sensitive and versatile gas-chromatographic and mass-spectrometric instruments for trace gas analysis. Ironically, only non-smelling constituents of breath, such as O(2), CO(2), H(2), and NO have so far been included in routine clinical breath analysis. The ;smell' of human breath, on the other hand, arises through a combination of volatile organic compounds (VOCs) of which several hundred have been identified to date. Most of these volatiles are systemic and are released in the gas-exchange between blood and air in the alveoli. The concentration of these compounds in the alveolar breath is related to the respective concentrations in blood. Measuring VOCs in exhaled breath allows for screening of disease markers, studying the uptake and effect of medication (pharmacokinetics), or monitoring physiological processes. There is a range of requirements for instruments for the analysis of a complex matrix, such as human breath. Mass-spectrometric techniques are particularly well suited for this task since they offer the possibility of detecting a large variety of interesting compounds. A further requirement is the ability to measure accurately in the concentration range of breath VOCs, i.e. between parts-per-trillion (pptv) and parts-per-million (ppmv) range. In the mid 1990's proton transfer reaction-mass spectrometry (PTR-MS) was developed as a powerful and promising tool for the analysis of VOCs in gaseous media. Soon thereafter these instruments became commercially available to a still growing user community and have now become standard equipment in many fields including environmental research, food and flavour science, as well as life sciences. Their high sensitivity for VOCs with detection limits down to sub-pptv levels without pre-concentration and their highly linear signal response over seven orders of magnitude make PTR-MS instruments valuable tools for exhaled breath analysis. The ;soft' chemical ionization process in PTR-MS largely avoids fragmentation, providing interpretable spectra without pre-separation. This is especially important for complex gas mixtures such as breath. Even more interesting, PTR-MS instruments analyse a gas sample in real-time and do not require any sample pre-treatment. This offers the possibility for online breath analysis with breath-to-breath resolution. This special issue on PTR-MS applications in medical research contains articles exploring different medical applications of PTR-MS. These applications include screening studies, where the breath composition of a large number of patients is investigated to, e.g., determine influences of demographic data on breath concentrations (Schwarz et al 2009 J. Breath Res. 3 027003). In online monitoring studies the breath of one subject is continuously measured, e.g., to study rapid changes in breath volatiles under physical exercise (King et al 2009 J. Breath Res. 3 027006). Other papers address more elementary breath research and discuss the interpretation of exhaled breath composition in the presence of fragmenting and overlapping compounds (Schwarz et al 2009 J. Breath Res. 3 027002), examine the different causes of variability in the measurement of breath samples (Thekedar et al 2009 J. Breath Res. 3 027007), and compare blood and breath concentrations directly (O'Hara et al 2009 J. Breath Res. 3 027005). Potential sources for breath markers are also explored, by analysing the head-space emissions from microbial culture samples (O'Hara and Mayhew 2009 J. Breath Res. 3 027001). Finally, a recent technological advancement in PTR-MS technology promises several advantages especially for breath gas analysis, which is demonstrated by on-line breath sampling with a PTR-time-of-flight (PTR-TOF) instrument (Herbig et al 2009 J. Breath Res. 3 027004)"
Keywords:
Notes:"PubMed-not-MEDLINEHerbig, Jens Amann, Anton eng England 2009/06/01 J Breath Res. 2009 Jun; 3(2):020201. doi: 10.1088/1752-7163/3/2/020201. Epub 2009 Jun 9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024