Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSemi-volatile organic compounds (SVOCs) in ambient air and rainwater in a tropical environment: concentrations and temporal and seasonal trends    Next Abstract"An unbiased approach elucidates variation in (S)-(+)-linalool, a context-specific mediator of a tri-trophic interaction in wild tobacco" »

Huan Jing Ke Xue


Title:[Source emission characteristics and impact factors of volatile halogenated organic compounds from wastewater treatment plant]
Author(s):He J; Wang BG; Liu SL; Zhao DJ; Tang XD; Zou Y;
Address:"Department of Environment Engineering, Jinan University, Guangzhou 510632, China. hejie198611@yahoo.com.cn"
Journal Title:Huan Jing Ke Xue
Year:2011
Volume:32
Issue:12
Page Number:3577 - 3581
DOI:
ISSN/ISBN:0250-3301 (Print) 0250-3301 (Linking)
Abstract:"A low enrichment method of using Tenax as absorbent and liquid nitrogen as refrigerant has been established to sample the volatile halogenated organic compounds in Guangzhou Liede municipal wastewater treatment plant as well as its ambient air. The composition and concentration of target halogenated hydrocarbons were analyzed by combined thermal desorption/GC-MS to explore its sources profile and impact factors. The result showed that 19 halogenated organic compounds were detected, including 11 halogenated alkanets, 3 halogenated alkenes, 3 halogenated aromatic hydrocarbons and 2 haloesters, with their total concentrations ranged from 34.91 microg x m(-3) to 127.74 microg x m(-3) and mean concentrations ranged from n.d. to 33.39 microg x m(-3). Main pollutants of the studied plant were CH2Cl2, CHCl3, CFC-12, C2H4Cl2, CFC-11, C2HCl3 and C2Cl4, they came from the wastewater by volatilization. Among the six processing units, the dehydration room showed the highest level of halogenated organic compounds, followed by pumping station, while the sludge thickener was the lowest. The emissions from pumping station, aeration tank and biochemical pool were significantly affected by temperature and humidity of environment"
Keywords:"Air Pollutants/analysis China Cities Environmental Monitoring/methods Gas Chromatography-Mass Spectrometry Halogens/*analysis Hydrocarbons, Halogenated/*analysis Organic Chemicals/*analysis Sewage/chemistry Volatile Organic Compounds/analysis/*chemistry *;"
Notes:"MedlineHe, Jie Wang, Bo-Guang Liu, Shu-Le Zhao, De-Jun Tang, Xiao-Dong Zou, Yu chi Research Support, Non-U.S. Gov't China 2012/04/04 Huan Jing Ke Xue. 2011 Dec; 32(12):3577-81"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024