J Air Waste Manage Assoc


Title:The validation of a passive sampler for indoor and outdoor concentrations of volatile organic compounds
Author(s):Cohen MA; Ryan PB; Yanagisawa Y; Hammond SK;
Address:"Harvard University, School of Public Health, Boston, Massachusetts"
Journal Title:J Air Waste Manage Assoc
Year:1990
Volume:40
Issue:7
Page Number:993 - 997
DOI: 10.1080/10473289.1990.10466751
ISSN/ISBN:1047-3289 (Print) 1047-3289 (Linking)
Abstract:"Volatile organics compounds (VOCs) are ubiquitous in the air we breathe. The use of passive samplers to measure these concentrations can be an effective technique. When exposed for long durations, a passive sampler may be a good tool for investigating chronic exposures to chemicals in the environment. A passive sampler that was designed for occupational exposures can be used as such a tool. Laboratory validation under as many conditions as possible needs to be accomplished so as to characterize the sampler with known parameters. This paper describes the methods and results of an investigation into the validity of using a passive monitor to sample VOCs for a three-week period. Two concentration levels, two relative humidities, and five VOCs were studied. Results indicate that the samplers work best under conditions of high concentration with low relative humidity and low concentration with high relative humidity. For the passive sampler, excluding chloroform, percent deviations from the predicted values varied between -41 and +22 percent; while the values between the passive and the active samplers varied between -27 and +24 percent. Benzene, heptane, and perchloroethylene were sampled with equal precision and accuracy"
Keywords:Air Pollutants/*analysis Evaluation Studies as Topic Hydrocarbons/*analysis;
Notes:"MedlineCohen, M A Ryan, P B Yanagisawa, Y Hammond, S K eng 1990/07/01 J Air Waste Manage Assoc. 1990 Jul; 40(7):993-7. doi: 10.1080/10473289.1990.10466751"

 