Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Ruthenium-catalyzed stereo- and chemoselective oxidative coupling of vinyl ketones: efficient access to (E,E)-1,6-dioxo-2,4-dienes"    Next Abstract"Synthesis, Functional Assays, Electrophysiological Activity, and Field Tests of Pheromone Antagonists of the Tomato Leafminer, Tuta absoluta" »

Sensors (Basel)


Title:Toward the Required Detection Limits for Volatile Organic Constituents in Marine Environments with Infrared Evanescent Field Chemical Sensors
Author(s):Dettenrieder C; Raichlin Y; Katzir A; Mizaikoff B;
Address:"Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany. Department of Physics, Faculty of Natural Sciences, Ariel University, Ariel 44837, Israel. School of Physics and Astronomy, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel. Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany. boris.mizaikoff@uni-ulm.de. Department of Chemical Sciences, University of Johannesburg, Johannesburg 2001, South Africa. boris.mizaikoff@uni-ulm.de"
Journal Title:Sensors (Basel)
Year:2019
Volume:20190821
Issue:17
Page Number: -
DOI: 10.3390/s19173644
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"A portable sensor system for the simultaneous detection of multiple environmentally relevant volatile organic compounds (VOCs) in real seawater based on Fourier transform infrared fiber-optic evanescent wave spectroscopy (FT-IR-FEWS) was developed. A cylindrical silver halide (AgX) fiber with an ethylene/propylene copolymer (E/P-co) coated flattened segment was used as an active optical transducer. The polymer membrane enriches the hydrophobic analytes, while water is effectively excluded from the penetration depth of the evanescent field. Determination of multicomponent mixtures (i.e., 10 VOCs in real-world seawater samples) collected in Arcachon Bay, France revealed a high accuracy and reproducibility with detection limits down to 560 ppb. The measurement showed no significant influence from changing water conditions (e.g., salinity, turbidity, and temperature or other interfering substances). The time constants for 90% saturation of the polymer ranged from 20 to 60 min. The sensor system is capable of being transported for on-site monitoring of environmental pollutants in aqueous matrices with efficient long-term stability, thus showing great potential to be utilized as an early warning system"
Keywords:Fourier transform infrared spectroscopy IR sensor Voc chemosensor enrichment environmental monitoring fiber-optic evanescent field sensor mid-infrared optical chemical sensor polymer coating silver halide fiber volatile organic compound;
Notes:"PubMed-not-MEDLINEDettenrieder, Carina Raichlin, Yosef Katzir, Abraham Mizaikoff, Boris eng Switzerland 2019/08/24 Sensors (Basel). 2019 Aug 21; 19(17):3644. doi: 10.3390/s19173644"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024