Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Chemical characterization of territorial marking fluid of male Bengal tiger, Panthera tigris"    Next Abstract"Identification, Synthesis, and Field Tests of the Sex Pheromone of Margarodes prieskaensis (Jakubski)" »

J Chromatogr A


Title:Development of second-generation sample enrichment probe for improved sorptive analysis of volatile organic compounds
Author(s):Burger BV; le Roux M; Marx B; Herbert SA; Amakali KT;
Address:"Laboratory for Ecological Chemistry, Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, South Africa. lecus@sun.ac.za"
Journal Title:J Chromatogr A
Year:2011
Volume:20110120
Issue:12
Page Number:1567 - 1575
DOI: 10.1016/j.chroma.2011.01.038
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"The sample enrichment probe (SEP) has recently been introduced as a user-friendly and cost-effective method for the sorptive extraction of volatile organic analytes from gaseous and aqueous samples for GC and GC-MS analyses. In a further development of the SEP technique, thinner polydimethylsiloxane (PDMS) tubing on polyimide-coated fused silica, instead of stainless steel rods or stalks, were used to produce the second-generation SEPs. The new SEP does not require widening of the needle-guiding orifice of the septum cap and analytes are desorbed at a faster rate from the thinner sleeve, which reduces the risk of carry-over. The flowless period that was previously recommended for analyses of highly volatile analytes is made redundant by the faster desorption from the thinner sorptive medium. It was found that differences in the thermal histories of SEPs are not the cause of the high relative standard deviations (RSDs) reported in our first paper on the technique. Excellent reproducibility can be attained by careful handling and storing of loaded SEPs and by rigorously following a standardised analytical protocol"
Keywords:Adsorption Alcohols/*analysis/isolation & purification Alkanes/analysis/isolation & purification Chemical Fractionation/*instrumentation/methods Dimethylpolysiloxanes Gas Chromatography-Mass Spectrometry Reproducibility of Results Volatile Organic Compoun;
Notes:"MedlineBurger, B V le Roux, M Marx, B Herbert, S A Amakali, K T eng Netherlands 2011/02/22 J Chromatogr A. 2011 Mar 25; 1218(12):1567-75. doi: 10.1016/j.chroma.2011.01.038. Epub 2011 Jan 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024