Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCloning of the glutamine:fructose-6-phosphate amidotransferase gene from yeast. Pheromonal regulation of its transcription    Next AbstractImproved accuracy in the determination of polycyclic aromatic hydrocarbons in air using 24 h sampling on a mixed bed followed by thermal desorption capillary gas chromatography-mass spectrometry »

Environ Monit Assess


Title:An evaluation of a fast sampling procedure for the trace analysis of volatile organic compounds in ambient air
Author(s):Wauters E; Walravens E; Muulle E; Verduyn G;
Address:"Institute for Hygiene and Epidemiology, Ministry of Public Health, J. Wytsmanstreet 14, 1050, Brussels, Belgium"
Journal Title:Environ Monit Assess
Year:1983
Volume:3
Issue:2
Page Number:151 - 160
DOI: 10.1007/BF00398844
ISSN/ISBN:0167-6369 (Print) 0167-6369 (Linking)
Abstract:"This study deals with the evaluation of a fast method for sampling of volatile organic compounds in ambient air. Special bags made of an inert material are used together with a large handpump which allows a sampling of one liter per second. After the sampling, the pollutants are concentrated by adsorption on Tenax and transfered by heat desorption, to a small capillary precolumn cooled with liquid nitrogen, or directly trapped on the precolumn. The suitability of this technique was evaluated by sampling complex synthetic mixtures of known concentration and composition, after which the samples were submitted to a series of operations such as transport, aging, changing of the humidity, heating and cooling, irradiation, etc. Changes in the original mixtures, caused by adsorption, diffusion, chemical or photochemical reactions were investigated by GC-MS analysis. The results of the study show that under certain conditions the samples can be preserved for a rather long period of time without noticeable changes in composition. However for certain compounds, severe quantitative losses occur after one day storage. Finally a practical application of this method is described in a recent case of strong odour annoyance by a chemical plant in the north of Belgium"
Keywords:
Notes:"PubMed-not-MEDLINEWauters, E Walravens, E Muulle, E Verduyn, G eng Netherlands 1983/06/01 Environ Monit Assess. 1983 Jun; 3(2):151-60. doi: 10.1007/BF00398844"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024