Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractComparison of consecutive harvests versus blending treatments to produce lower alcohol wines from Cabernet Sauvignon grapes: Impact on wine volatile composition and sensory properties    Next AbstractA comparison of the contribution of the major histocompatibility complex (MHC) and Y chromosomes to the discriminability of individual urine odors of mice by Long-Evans rats »

J Chromatogr A


Title:Miniaturized membrane-assisted solvent extraction combined with gas chromatography/electron-capture detection applied to the analysis of volatile organic compounds
Author(s):Schellin M; Popp P;
Address:"Department of Analytical Chemistry, UFZ-Centre for Environmental Research, Permoserstrasse 15, 04318 Leipzig, Germany. manuela.schellin@ufz.de"
Journal Title:J Chromatogr A
Year:2006
Volume:20051201
Issue:2
Page Number:211 - 218
DOI: 10.1016/j.chroma.2005.11.010
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A new module of membrane-assisted solvent extraction (MASE) with miniaturized membrane bags was applied to the determination of seven volatile organic compounds (VOCs): chloroform, 1,1,1-trichloroethane, trichloroethylene, 1,1,2-trichloroethane, tetrachloroethene, 1,1,1,2-tetrachloroethane, 1,1,2,2-tetrachloroethane with boiling points between 61 and 147 degrees C in aqueous samples. Different from the known procedure the new, shortened membrane bags were filled with 100 microl of an organic solvent. The membrane bags were placed in a 20 ml headspace vial and filled with 15 ml of the aqueous sample. The vial was transferred into an autosampler where it was stirred for a definite time at elevated temperature. After the extraction, 1 microl of the organic extract was transferred into the spilt/splitless injector of a GC system equipped with an electron-capture detector. This work included optimization of the membrane device, the determination of the optimized extraction conditions such as stirring rate, extraction time and the impact of salt addition. The validation of the method involved repeatability, recovery and detection limit studies, followed of its application towards real water samples. The repeatability, expressed as the relative standard deviation of the peak areas of six extractions was below 10%. The detection limits (LODs) were between 5 ng/l (tetrachloroethene) and 50 ng/l (chloroform). Calibration was performed in a range from 5 ng/l to 150 microg/l, since the concentration in the aqueous samples was expected quite various in this concentration range. Five river water samples of Bitterfeld, Saxony-Anhalt, Germany were analyzed with miniaturized-MASE and the results were compared with those obtained with Headspace-Analysis. The method can be fully automated and moreover, it allows the simultaneous determination of volatile and semi volatile compounds"
Keywords:"Chromatography, Gas/*methods Electrons Gas Chromatography-Mass Spectrometry/methods Hydrocarbons, Chlorinated/*analysis Hypophysectomy, Chemical/instrumentation/*methods Membranes, Artificial Volatilization Water Pollutants, Chemical/*analysis;"
Notes:"MedlineSchellin, Manuela Popp, Peter eng Validation Study Netherlands 2005/12/06 J Chromatogr A. 2006 Jan 27; 1103(2):211-8. doi: 10.1016/j.chroma.2005.11.010. Epub 2005 Dec 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024