Micromachines (Basel)


Title:Micro Milled Microfluidic Photoionization Detector for Volatile Organic Compounds
Author(s):Rezende GC; Le Calve S; Brandner JJ; Newport D;
Address:"Bernal Institute, School of Engineering, University of Limerick, V94 T9PX Limerick, Ireland. gustavo.coelho@ul.ie. Universite de Strasbourg, Centre national de la recherche scientifique (CNRS), ICPEES UMR 7515, F-67087 Strasbourg, France. slecalve@unistra.fr. In'Air Solutions, 25 rue Becquerel, 67087 Strasbourg, France. slecalve@unistra.fr. Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany. juergen.brandner@kit.edu. Bernal Institute, School of Engineering, University of Limerick, V94 T9PX Limerick, Ireland. david.newport@ul.ie"
Journal Title:Micromachines (Basel)
Year:2019
Volume:20190330
Issue:4
Page Number: -
DOI: 10.3390/mi10040228
ISSN/ISBN:2072-666X (Print) 2072-666X (Electronic) 2072-666X (Linking)
Abstract:Government regulations and environmental conditions are pushing the development of improved miniaturized gas analyzers for volatile organic compounds. One of the many detectors used for gas analysis is the photoionization detector (PID). This paper presents the design and characterization of a microfluidic photoionization detector (or microPID) fabricated using micro milling and electrical discharge machining techniques. This device has no glue and facilitates easy replacement of components. Two materials and fabrication techniques are proposed to produce a layer on the electrodes to protect from ultraviolet (UV) light and possible signal noise generation. Three different microchannels are tested experimentally and their results are compared. The channel with highest electrode area (31.17 mm(2)) and higher volume (6.47 microL) produces the highest raw signal and the corresponding estimated detection limit is 0.6 ppm for toluene without any amplification unit
Keywords:microfabrication microfluidics photoionization detector toluene volatile organic compound (VOC) detection;
Notes:"PubMed-not-MEDLINERezende, Gustavo C Le Calve, Stephane Brandner, Jurgen J Newport, David eng 643095/Horizon 2020 Framework Programme/ Switzerland 2019/04/03 Micromachines (Basel). 2019 Mar 30; 10(4):228. doi: 10.3390/mi10040228"

 