Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFirst investigation on ultrasound-assisted preparation of food products: sensory and physicochemical characteristics    Next AbstractDetailed chemical analysis of regional-scale air pollution in western Portugal using an adapted version of MCM v3.1 »

J Toxicol Environ Health A


Title:Indoor air quality in Portuguese archives: a snapshot on exposure levels
Author(s):Pinheiro AC; Viegas C; Viegas S; Verissimo C; Brandao J; Macedo MF;
Address:"Departamento de Conservacao e Restauro da Faculdade de Ciencias e Tecnologia da Universidade Nova de Lisboa, Caparica, Portugal. catmarpin@gmail.com"
Journal Title:J Toxicol Environ Health A
Year:2012
Volume:75
Issue:22-23
Page Number:1359 - 1370
DOI: 10.1080/15287394.2012.721168
ISSN/ISBN:1528-7394 (Print) 0098-4108 (Linking)
Abstract:"Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO(2)), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM(1)(0)), and ozone (O(3)) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM(1)(0), O(3), and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping"
Keywords:"Air Microbiology Air Pollutants/analysis/toxicity *Air Pollution, Indoor/adverse effects/legislation & jurisprudence/prevention & control *Archives Certification Colony Count, Microbial *Environmental Exposure/adverse effects/prevention & control Environm;"
Notes:"MedlinePinheiro, A C Viegas, C Viegas, S Verissimo, C Brandao, J Macedo, M F eng Research Support, Non-U.S. Gov't England 2012/10/26 J Toxicol Environ Health A. 2012; 75(22-23):1359-70. doi: 10.1080/15287394.2012.721168"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024