Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInduction of purple sulfur bacterial growth in dairy wastewater lagoons by circulation    Next Abstract"Microbial cycling of isoprene, the most abundantly produced biological volatile organic compound on Earth" »

AIHAJ


Title:The effects of adsorption on the reusability of Tedlar air sampling bags
Author(s):McGarvey LJ; Shorten CV;
Address:"Department of Health, West Chester University, PA 19383, USA"
Journal Title:AIHAJ
Year:2000
Volume:61
Issue:3
Page Number:375 - 380
DOI: 10.1080/15298660008984546
ISSN/ISBN:1529-8663 (Print) 1529-8663 (Linking)
Abstract:"This study examined the adsorption and desorption behavior of six different organic compounds in Tedlar bags. Triplicate bags were filled with a gas mixture to yield concentrations of approximately 90 ppm of each analyte, then sampled and analyzed by capillary gas chromatography at predetermined intervals over a 3-week period. A first-order kinetic rate equation was fitted to the data, and measured rate coefficients for the six compounds ranged from zero for the nonadsorbing methyl tert-butyl ether to 0.09/day for the rapidly adsorbed methanol. Adsorptive losses of allyl alcohol, styrene, ethylbenzene, and propylene oxide were slower and less significant; rate coefficients ranged from 0.01 to 0.03/day. Following the adsorption phase of the study, the bags were put through a simple cleaning procedure consisting of N2-flushing and gentle heating steps. Analysis of variance was used to assess the effectiveness of each step. Five N2 flushes were adequate to remove residual methyl tert-butyl ether, allyl alcohol, and propylene oxide, but there seemed to be a degree of hysteresis for styrene and ethylbenzene. Combinations of flushing and heating also failed to remove all the styrene and ethylbenzene. Neither flushing nor heating removed any of the adsorbed methanol. Depending on the compound of concern, the reuse of Tedlar and other similar polyvinyl fluoride sample collection bags should be carefully considered before the start of any sampling program"
Keywords:"Adsorption Air Pollutants/*analysis Analysis of Variance Chromatography, Gas Environmental Monitoring/*instrumentation Kinetics Polymers Regression Analysis Solvents/*analysis Volatilization;"
Notes:"MedlineMcGarvey, L J Shorten, C V eng Research Support, Non-U.S. Gov't 2000/07/08 AIHAJ. 2000 May-Jun; 61(3):375-80. doi: 10.1080/15298660008984546"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024