Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMunicipal Sewage Sludge as a Source for Obtaining Efficient Biosorbents: Analysis of Pyrolysis Products and Adsorption Tests    Next AbstractChemoresponsiveness and breath physiology in anosmia »

Adv Exp Med Biol


Title:Non-invasive assessment of exhaled breath pattern in patients with multiple chemical sensibility disorder
Author(s):Mazzatenta A; Pokorski M; Cozzutto S; Barbieri P; Veratti V; Di Giulio C;
Address:"Department of Neuroscience and Imaging, University of Chieti-Pescara, Chieti, Italy. amazzatenta@yahoo.com"
Journal Title:Adv Exp Med Biol
Year:2013
Volume:756
Issue:
Page Number:179 - 188
DOI: 10.1007/978-94-007-4549-0_23
ISSN/ISBN:0065-2598 (Print) 0065-2598 (Linking)
Abstract:"Multiple chemical sensitivity (MCS) is a complex disorder initiated by chemical exposure, particularly through the airways. MCS patients report sensitivity or intolerance to low levels of a wide spectrum of chemicals. Symptoms could include asthma-like signs, rhinitis, fatigue, cognitive dysfunction, psycho-physiological alteration, and other specific tissue reactions resembling hypoxic and oxidative stress effects. To recognize physiological signs that would allow the diagnosis of MCS in a non-invasive way we investigated the potential application of a new sensor system. In healthy volunteers, we measured exhaled breath content in the control condition and under exposure to olfactory stressors that mimic hypoxic or pollutant stressors playing a potential role in the generation of the MCS disorder. The recording system used is based on metal oxide semiconductor (MOS) sensor having a sensing range of 450-2,000 ppm CO(2) equivalents, which is able to detect a broad range of compounds playing a potential role in the generation of the MCS disorder, while correlating directly with the CO(2) levels. The results indicate that the recording system employed was suitable for the analysis of exhaled breath content in humans. Interestingly, the system was able to detect and discriminate between the exhaled breath content taken from the control condition and those from conditions under stress that mimicked exposures to pollutant or hypoxia. The results suggest that chronic hypoxia could be involved in the MCS disorder"
Keywords:Biomarkers/analysis *Breath Tests Carbon Dioxide/analysis Exhalation Humans Hypoxia/chemically induced Multiple Chemical Sensitivity/*diagnosis Oxidative Stress Respiratory Tract Diseases/*chemically induced Smell Volatile Organic Compounds/analysis/*toxi;neuroscience;
Notes:"MedlineMazzatenta, Andrea Pokorski, Mieczyslaw Cozzutto, Sergio Barbieri, Pierluigi Veratti, Vittore Di Giulio, Camillo eng 2012/07/28 Adv Exp Med Biol. 2013; 756:179-88. doi: 10.1007/978-94-007-4549-0_23"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024