Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIn vivo real-time monitoring of aphrodisiac pheromone release of small white cabbage butterflies (Pieris rapae)    Next AbstractDoes Aphid Infestation Interfere with Indirect Plant Defense against Lepidopteran Caterpillars in Wild Cabbage? »

J Chromatogr A


Title:Development of a short path thermal desorption-gas chromatography/mass spectrometry method for the determination of polycyclic aromatic hydrocarbons in indoor air
Author(s):Li Y; Xian Q; Li L;
Address:"Shanghai Academy of Environmental Sciences, Shanghai, China; State Environmental Protection Key Laboratory of the Cause and Prevention of Urban Air Pollution Complex, Shanghai, China; College of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, Shanghai, China. Electronic address: Liyj@saes.sh.cn. State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China. Shanghai Academy of Environmental Sciences, Shanghai, China; State Environmental Protection Key Laboratory of the Cause and Prevention of Urban Air Pollution Complex, Shanghai, China"
Journal Title:J Chromatogr A
Year:2017
Volume:20170327
Issue:
Page Number:127 - 134
DOI: 10.1016/j.chroma.2017.03.050
ISSN/ISBN:1873-3778 (Electronic) 0021-9673 (Linking)
Abstract:"Polycyclic aromatic hydrocarbons (PAHs) are present in petroleum based products and are combustion by-products of organic matters. Determination of levels of PAHs in the indoor environment is important for assessing human exposure to these chemicals. A new short path thermal desorption (SPTD) gas chromatography/mass spectrometry (GC/MS) method for determining levels of PAHs in indoor air was developed. Thermal desorption (TD) tubes packed with glass beads, Carbopack C, and Carbopack B in sequence, were used for sample collection. Indoor air was sampled using a small portable pump over 7 days at 100ml/min. Target PAHs were thermally released and introduced into the GC/MS for analysis through the SPTD unit. During tube desorption, PAHs were cold trapped (-20 degrees C) at the front end of the GC column. Thermal desorption efficiencies were 100% for PAHs with 2 and 3 rings, and 99-97% for PAHs with 4-6 rings. Relative standard deviation (RSD) values among replicate samples spiked at three different levels were around 10-20%. The detection limit of this method was at or below 0.1mug/m(3) except for naphthalene (0.61mug/m(3)), fluorene (0.28mug/m(3)) and phenanthrene (0.35mug/m(3)). This method was applied to measure PAHs in indoor air in nine residential homes. The levels of PAHs in indoor air found in these nine homes are similar to indoor air values reported by others"
Keywords:"Adsorption Air Pollution, Indoor/*analysis Fluorenes/analysis *Gas Chromatography-Mass Spectrometry Glass/chemistry Humans Limit of Detection Naphthalenes/analysis Phenanthrenes/analysis Polycyclic Aromatic Hydrocarbons/*analysis/chemistry Gas chromatogra;"
Notes:"MedlineLi, Yingjie Xian, Qiming Li, Li eng Netherlands 2017/04/04 J Chromatogr A. 2017 May 12; 1497:127-134. doi: 10.1016/j.chroma.2017.03.050. Epub 2017 Mar 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024