Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBehavior of organic polymers in drinking water purification    Next AbstractChanges of headspace volatiles in milk with riboflavin photosensitization »

J Chromatogr A


Title:Determination of optimum conditions for the analysis of volatile components in pine needles by double-shot pyrolysis-gas chromatography-mass spectrometry
Author(s):Lee JG; Lee CG; Kwag JJ; Buglass AJ; Lee GH;
Address:"Department of Tobacco Research, KT&G Central Research Institute, Yuseong-gu, Daejeon 305-805, South Korea. jgolee@ktng.com"
Journal Title:J Chromatogr A
Year:2005
Volume:1089
Issue:1-Feb
Page Number:227 - 234
DOI: 10.1016/j.chroma.2005.06.060
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"The optimum conditions for the analysis of the volatile organic components of pine needles from Pinus densiflora using double-shot pyrolysis-gas chromatography-mass spectrometry (DSP-GC-MS) were investigated with respect to thermal desorption temperature and duration of heating. A total of 41 compounds were identified using thermal desorption temperatures of 150 degrees C, 200 degrees C, 250 degrees C and 300 degrees C. Thermal decomposition products, which include acetol, acetic acid, furfurals and phenols, were observed only at thermal desorption temperatures exceeding 250 degrees C: they were not observed in the extract from a simultaneous distillation extraction (SDE) method. Heating times of 1 s, 6 s, 30 s, 150 s and 300 s were investigated at the thermal desorption temperature of 200 degrees C, whence it was found that thermal decomposition products were produced only at heating times over 30 s. The optimum pyrolyzer conditions for the analysis of pine needles using DSP-GC-MS is 200 degrees C for 6 s. Under these conditions, this method gives comparable results to the SDE method"
Keywords:Gas Chromatography-Mass Spectrometry/*methods Pinus/*chemistry Plant Leaves/*chemistry Volatilization;
Notes:"MedlineLee, Jae-Gon Lee, Chang-Gook Kwag, Jae-Jin Buglass, Alan J Lee, Gae-Ho eng Netherlands 2005/09/01 J Chromatogr A. 2005 Sep 30; 1089(1-2):227-34. doi: 10.1016/j.chroma.2005.06.060"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024