Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Metamorphosis-related changes in the free fatty acid profiles of Sarcophaga (Liopygia) argyrostoma (Robineau-Desvoidy, 1830)"    Next Abstract"Flubendiamide, the first phthalic acid diamide insecticide, impairs neuronal calcium signalling in the honey bee's antennae" »

Sensors (Basel)


Title:Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
Author(s):Kaczmarek W; Panasiuk J; Borys S; Pobudkowska A; Majsterek M;
Address:"Faculty of Mechatronics and Aerospace, Military University of Technology, Kaliskiego 2 Street, 00-908 Warsaw, Poland. Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3 Street, 00-664 Warsaw, Poland. Virtual Power Plant Sp. z.o.o., Dubois 114/116 Street premises 2.30, 93-465 Lodz, Poland"
Journal Title:Sensors (Basel)
Year:2020
Volume:20200826
Issue:17
Page Number: -
DOI: 10.3390/s20174820
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a need to develop a system that can predict the formation of chlorine water disinfection by-products, such as trihalomethanes (THMs). THMs are volatile organic compounds from the group of alkyl halides, carcinogenic, mutagenic, teratogenic, and bioaccumulating. Long-term exposure, even to low concentrations of THM in water and air, may result in damage to the liver, kidneys, thyroid gland, or nervous system. This article focuses on analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale. The designed and constructed analytical device is based on the SIMATIC S7-1200 PLC driver of SIEMENS Company. The HMI KPT panel of SIEMENS Company enables monitoring the process and control individual elements of device. Value of the reaction rate constant of free chlorine decomposition gives us qualitative information about water quality, it is also strictly connected to the kinetics of the reaction. Based on the experiment results, the value of reaction rate constant was determined as a linear change of the natural logarithm of free chlorine concentration over time. The experimental value of activation energy based on the directional coefficient is equal to 76.0 [kJxmol-1]. These results indicate that changing water temperature does not cause any changes in the reaction rate, while it still affects the value of the reaction rate constant. Using the analytical device, it is possible to constantly monitor the values of reaction rate constant and activation energy, which can be used to develop a new way to assess pool water quality"
Keywords:Oht Plc Thm algorithm analytical device testing of water parameters;
Notes:"PubMed-not-MEDLINEKaczmarek, Wojciech Panasiuk, Jaroslaw Borys, Szymon Pobudkowska, Aneta Majsterek, Mikolaj eng POIR.01.01.01-00-0460/16-00/Narodowe Centrum Badan i Rozwoju/ Switzerland 2020/08/30 Sensors (Basel). 2020 Aug 26; 20(17):4820. doi: 10.3390/s20174820"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024