Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Comparative study of the adsorption performance of an active multi-sorbent bed tube (Carbotrap, Carbopack X, Carboxen 569) and a Radiello((R)) diffusive sampler for the analysis of VOCs"    Next AbstractCharacterization and determination of the odorous charge in the indoor air of a waste treatment facility through the evaluation of volatile organic compounds (VOCs) using TD-GC/MS »

J Environ Monit


Title:Evaluation of the effect of different sampling time periods and ambient air pollutant concentrations on the performance of the Radiello diffusive sampler for the analysis of VOCs by TD-GC/MS
Author(s):Gallego E; Roca FJ; Perales JF; Guardino X;
Address:"Laboratori del Centre de Medi Ambient, Universitat Politecnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028, Barcelona, Spain. Lcma.info@upc.edu"
Journal Title:J Environ Monit
Year:2011
Volume:20110810
Issue:9
Page Number:2612 - 2622
DOI: 10.1039/c1em10075k
ISSN/ISBN:1464-0333 (Electronic) 1464-0325 (Linking)
Abstract:"The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello(R) samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello(R) passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello(R) passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed"
Keywords:Adsorption Air Pollutants/*analysis Environmental Monitoring/instrumentation/*methods Gas Chromatography-Mass Spectrometry Time Factors Volatile Organic Compounds/*analysis;
Notes:"MedlineGallego, E Roca, F J Perales, J F Guardino, X eng Evaluation Study Research Support, Non-U.S. Gov't England 2011/08/11 J Environ Monit. 2011 Sep; 13(9):2612-22. doi: 10.1039/c1em10075k. Epub 2011 Aug 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-07-2024