Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExpression pattern analysis of odorant-binding proteins in the pea aphid Acyrthosiphon pisum    Next Abstract"Atmospheric carbon tetrachloride in rural background and industry surrounded urban areas in Northern Iberian Peninsula: Mixing ratios, trends, and potential sources" »

Sci Total Environ


Title:Automatic on-line monitoring of atmospheric volatile organic compounds: gas chromatography-mass spectrometry and gas chromatography-flame ionization detection as complementary systems
Author(s):de Blas M; Navazo M; Alonso L; Durana N; Iza J;
Address:"Chemical and Environmental Engineering Department, University College of Technical Mining and Civil Engineering, University of the Basque Country, Colina de Beurco s/n, 48902 Barakaldo, Spain. maite.deblas@ehu.es"
Journal Title:Sci Total Environ
Year:2011
Volume:20111005
Issue:24
Page Number:5459 - 5469
DOI: 10.1016/j.scitotenv.2011.08.072
ISSN/ISBN:1879-1026 (Electronic) 0048-9697 (Linking)
Abstract:"Traditionally air quality networks have been carrying out the continuous, on-line measurement of volatile organic compounds (VOC) in ambient air with GC-FID. In this paper some identification and coelution problems observed while using this technique in long-term measurement campaigns are described. In order to solve these problems a GC-MS was set up and operated simultaneously with a GC-FID for C2-C11 VOCs measurement. There are few on-line, unattended, long term measurements of atmospheric VOCs performed with GC-MS. In this work such a system has been optimized for that purpose, achieving good repeatability, linearity, and detection limits of the order of the GC-FID ones, even smaller in some cases. VOC quantification has been made by using response factors, which is not frequent in on-line GC-MS. That way, the identification and coelution problems detected in the GC-FID, which may led to reporting erroneous data, could be corrected. The combination of GC-FID and GC-MS as complementary techniques for the measurement of speciated VOCs in ambient air at sub-ppbv levels is proposed. Some results of the measurements are presented, including concentration values for some compounds not found until now on public ambient air VOC databases, which were identified and quantified combining both techniques. Results may also help to correct previously published VOC data with wrongly identified compounds by reprocessing raw chromatographic data"
Keywords:"Air Pollutants/*analysis Chromatography, Gas Cities Environmental Monitoring/*methods Flame Ionization Gas Chromatography-Mass Spectrometry Hydrocarbons, Aromatic/analysis Hydrocarbons, Chlorinated/analysis Online Systems/instrumentation Spain Volatile Or;"
Notes:"Medlinede Blas, Maite Navazo, Marino Alonso, Lucio Durana, Nieves Iza, Jon eng Evaluation Study Research Support, Non-U.S. Gov't Netherlands 2011/10/08 Sci Total Environ. 2011 Nov 15; 409(24):5459-69. doi: 10.1016/j.scitotenv.2011.08.072. Epub 2011 Oct 5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024