Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractResource exploitation strategies in the presence of traffic between food sources    Next AbstractOptimization of FLEC-SPME for field passive sampling of VOCs emitted from solid building materials »

J Chromatogr A


Title:Solid phase microextraction sampling for a rapid and simple on-site evaluation of volatile organic compounds emitted from building materials
Author(s):Nicolle J; Desauziers V; Mocho P;
Address:"Laboratoire Genie de l'Environnement Industriel, Ecole des Mines d'Ales, Helioparc, 2 avenue Pierre Angot, 64053 Pau Cedex 9, France"
Journal Title:J Chromatogr A
Year:2008
Volume:20080820
Issue:1-Feb
Page Number:10 - 15
DOI: 10.1016/j.chroma.2008.08.061
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A new sampling method was developed for a simple and fast evaluation of volatile organic compounds (VOCs) emitted at trace levels from building materials. The device involves an emission cell coupled with solid phase microextraction (SPME) for diffusive sampling. Owing to possible competitive adsorption of VOCs onto the PDMS-Carboxen fiber used, the co-adsorption conditions were determined through kinetics study of isolated and in mixture compounds. Hence, the linear concentration ranges which ensure reliable quantification were determined from 4.8 to 10mgm(-3)min according to the VOC studied. Thus, the analyst can select the extraction time that fits for his best analytical objectives. For example, sub microgm(-3) limits of detection can be achieved for GC-MS analysis for 20min extraction. On the other hand, 5min sampling is sufficient for a rapid screening of the major emitted VOCs, since the average limit of quantification reaches 20microgm(-3) for GC-FID analysis"
Keywords:"Air Pollution, Indoor/*analysis Environmental Monitoring/*methods Gas Chromatography-Mass Spectrometry/*methods Organic Chemicals/*analysis Sensitivity and Specificity Solid Phase Microextraction/*methods Volatilization;"
Notes:"MedlineNicolle, Jerome Desauziers, Valerie Mocho, Pierre eng Research Support, Non-U.S. Gov't Netherlands 2008/09/06 J Chromatogr A. 2008 Oct 24; 1208(1-2):10-5. doi: 10.1016/j.chroma.2008.08.061. Epub 2008 Aug 20"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024