Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSocial Behavioral Deficits with Loss of Neurofibromin Emerge from Peripheral Chemosensory Neuron Dysfunction    Next AbstractSpoilage markers for freshwater fish: A comprehensive workflow for non-targeted analysis of VOCs using DHS-GC-HRMS »

Contact Dermatitis


Title:Stability of selected volatile contact allergens in different patch test chambers under different storage conditions
Author(s):Mose KF; Andersen KE; Christensen LP;
Address:"Department of Dermatology and Allergy Centre, Odense University Hospital, DK-5000 Odense C, Denmark"
Journal Title:Contact Dermatitis
Year:2012
Volume:66
Issue:4
Page Number:172 - 179
DOI: 10.1111/j.1600-0536.2011.02035.x
ISSN/ISBN:1600-0536 (Electronic) 0105-1873 (Linking)
Abstract:"BACKGROUND: Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. OBJECTIVES: To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. METHODS: Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber, IQ Ultimate, and Van der Bend(R) transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. RESULTS: The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber and IQ Ultimate, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend(R) transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. CONCLUSION: The Van der Bend(R) transport container was the best device for storage of samples of volatile contact allergens"
Keywords:"Acrolein/*analogs & derivatives/chemistry Acrylates/*chemistry Allergens/chemistry Chromatography, High Pressure Liquid Dermatitis, Allergic Contact/*diagnosis Drug Stability Drug Storage Eugenol/*chemistry Flavoring Agents/chemistry Humans Methacrylates/;"
Notes:"MedlineMose, Kristian F Andersen, Klaus E Christensen, Lars Porskjaer eng England 2012/03/13 Contact Dermatitis. 2012 Apr; 66(4):172-9. doi: 10.1111/j.1600-0536.2011.02035.x"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024