Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRegulatory subunit (CNB1 gene product) of yeast Ca2+/calmodulin-dependent phosphoprotein phosphatases is required for adaptation to pheromone    Next AbstractSynergy between social and private information increases foraging efficiency in ants »

Sci Total Environ


Title:PM25 measurements in ambient aerosol: comparison between Harvard impactor (HI) and the tapered element oscillating microbalance (TEOM) system
Author(s):Cyrys J; Dietrich G; Kreyling W; Tuch T; Heinrich J;
Address:"GSF-National Research Center for Environment and Health, Institute of Epidemiology, Neuherberg, Germany. cyrys@gsf.de"
Journal Title:Sci Total Environ
Year:2001
Volume:278
Issue:1-Mar
Page Number:191 - 197
DOI: 10.1016/s0048-9697(01)00648-9
ISSN/ISBN:0048-9697 (Print) 0048-9697 (Linking)
Abstract:"A comparison, based on the regression of 32 daily mean PM25 aerosol loadings determined by a tapered element oscillating microbalance (TEOM) and by a Harvard impactor (HI), is reported for the ambient aerosol of Erfurt (Germany). The PM2.5 concentrations measured by the TEOM were systematically lower then those obtained by the HI. The ratio of the means TEOM/HI was 0.74 and the regression equation is TEOM = 0.69 x HI + 0.071. This result is consistent with reports elsewhere suggesting that semi-volatile aerosol material is lost from the heated sample filter on the TEOM. To verify this assertion, a heating system was developed for the HI which was able to keep the HI sample filter at 50+/-1 degrees C. After the implementation of this heating system, no systematically differences were observed between the TEOM and the heated HI system. The ratio of means was 1.06 and the regression equation TEOM = 1.10 x HI - 0.668. Because the measured levels of ammonium nitrate were very low in Erfurt, we concluded that other compounds like semi-volatile organics were responsible for the loss of particulate material at 50 degrees C"
Keywords:Aerosols Air Pollution/*analysis Environmental Monitoring/*instrumentation/*methods Filtration Particle Size Regression Analysis Temperature Volatilization;
Notes:"MedlineCyrys, J Dietrich, G Kreyling, W Tuch, T Heinrich, J eng Comparative Study Netherlands 2001/10/24 Sci Total Environ. 2001 Oct 20; 278(1-3):191-7. doi: 10.1016/s0048-9697(01)00648-9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024