Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIn situ analysis of solvents on breath and blood: a selected ion flow tube mass spectrometric study    Next AbstractEppendorf 2007 winner. Neural circuits underlying chemical perception »

Talanta


Title:High throughput analysis of atmospheric volatile organic compounds by thermal injection--isothermal gas chromatography--time-of-flight mass spectrometry
Author(s):Wilson RB; Hoggard JC; Synovec RE;
Address:"Department of Chemistry, Box 351700, University of Washington Seattle, Washington 98195-1700, USA"
Journal Title:Talanta
Year:2013
Volume:20121012
Issue:
Page Number:95 - 102
DOI: 10.1016/j.talanta.2012.10.013
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"Sixty one volatile organic compounds (VOCs) from a standard gas mixture were separated via isothermal gas chromatography coupled with time-of-flight mass spectrometry (GC-TOFMS) in a approximately 35s separation time window ( approximately 45 s separation). The VOCs in the standard gas mixture were selected based on the EPA TO-15 methodology. The high throughput separation was achieved with a relatively high total peak capacity (n(c) approximately 114), by simultaneously minimizing both on-column and off-column peak width broadening. The on-column contributions to peak width broadening were minimized by taking into account and applying GC separation theory for the selection of column dimensions and carrier gas flow rate conditions. Both fast cryogenic focusing and re-injection of compounds (implemented via a commercially available thermal modulator and referred to herein as thermal injection (TI) and fast TOFMS detection (100 scans/s)) were applied to reduce off-column sources of peak width band broadening (sometimes referred to as off-column band broadening). Cryogenic focusing during TI and minimal band broadening-based dilution during separation resulted in preconcentration factors for the detected peaks ranging from 78 (1,4-dichlorobenzene) to 420 (propylene). Since the injected volume for preconcentration was 500 mul, and based on the detected noise levels at selected m/z for each analyte compound, the concentration limit of detection (LOD) ranged from 67 ppbv (parts per billion by volume) for propylene, to 4 ppbv for freon-12. While application of standard VOC analysis conditions leads to separation times typically ranging from approximately 30 to 50 min, the isothermal GC-TOFMS method reported herein represents a 40-fold improvement in analysis time while maintaining peak capacity and detection sensitivity that is comparable to traditional GC-MS VOC analysis"
Keywords:"*Gas Chromatography-Mass Spectrometry *High-Throughput Screening Assays Limit of Detection Models, Theoretical Volatile Organic Compounds/*analysis;"
Notes:"MedlineWilson, Ryan B Hoggard, Jamin C Synovec, Robert E eng Research Support, U.S. Gov't, Non-P.H.S. Netherlands 2012/12/04 Talanta. 2013 Jan 15; 103:95-102. doi: 10.1016/j.talanta.2012.10.013. Epub 2012 Oct 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024