Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractNanoscale Sensor Technologies for Disease Detection via Volatolomics    Next AbstractMethylated sulfur compounds in microbial mats: in situ concentrations and metabolism by a colorless sulfur bacterium »

Talanta


Title:Evaluation of settled floor dust for the presence of microbial metabolites and volatile anthropogenic chemicals in indoor environments by LC-MS/MS and GC-MS methods
Author(s):Vishwanath V; Sulyok M; Weingart G; Kluger B; Taubel M; Mayer S; Schuhmacher R; Krska R;
Address:"Center for Analytical Chemistry (CAC), Department IFA-Tulln, Konrad Lorenz Strasse 20, A-3430 Tulln, Austria"
Journal Title:Talanta
Year:2011
Volume:20110719
Issue:4
Page Number:2027 - 2038
DOI: 10.1016/j.talanta.2011.07.043
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"This study reports on detection of a large number of biological and anthropogenic pollutants using LC-MS/MS and GC-MS technologies in settled floor dust (SFD). The latter technique was applied to obtain a general picture on the presence of microbial as well as non-microbial volatile organic compounds, whereas the targeted LC-MS/MS analysis focused on identification of species specific secondary metabolites. In the absence of moisture monitoring data the relevance of finding of stachybotrylactam and other metabolites of tertiary colonizers are confined only to accidental direct exposure to SFD. To the best of our knowledge 30 of the 71 identified volatile organic compounds (VOCs) are newly reported in SFD matrix. Coordinated application of 'AMDIS and Spectconnect' was found beneficial for the evaluation and identification of prime volatile pollutants in complex environmental samples. Principal component analysis (PCA) of peak areas of 18 microbial volatile organic compounds (MVOCs) resulted in identification of nonanal as potential MVOC marker. Two more volatiles toluene and 1-tetradecanol though had discriminative influence, are not regarded as MVOC markers, considering their probable alternate origin from paints and cosmetics, respectively"
Keywords:"Air Pollution, Indoor/*analysis Chromatography, Liquid/*methods Dust/*analysis Gas Chromatography-Mass Spectrometry/*methods *Microbiology Solid Phase Microextraction Tandem Mass Spectrometry/*methods Volatilization;"
Notes:"MedlineVishwanath, Vinay Sulyok, Michael Weingart, Georg Kluger, Bernhard Taubel, Martin Mayer, Stefan Schuhmacher, Rainer Krska, Rudolf eng Research Support, Non-U.S. Gov't Netherlands 2011/08/30 Talanta. 2011 Sep 30; 85(4):2027-38. doi: 10.1016/j.talanta.2011.07.043. Epub 2011 Jul 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024