Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Identification of trail pheromone precursors from Subterranean termite,Coptotermes formosanus Shiraki (Isoptera: Rhinotermitidae)"    Next AbstractComparison of rates of direct and indirect migration of phosphorus flame retardants from flame-retardant-treated polyester curtains to indoor dust »

Chemosphere


Title:Method of removal of volatile organic compounds by using wet scrubber coupled with photo-Fenton reaction--preventing emission of by-products
Author(s):Tokumura M; Wada Y; Usami Y; Yamaki T; Mizukoshi A; Noguchi M; Yanagisawa Y;
Address:"Department of Environment Systems, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan. masahiro.tokumura@veritas-sys.jp"
Journal Title:Chemosphere
Year:2012
Volume:20120804
Issue:10
Page Number:1238 - 1242
DOI: 10.1016/j.chemosphere.2012.07.018
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"The photo-Fenton reaction was applied as a novel method for the removal of volatile organic compounds (VOCs) in the gas phase, and its effectiveness was experimentally examined. In conventional VOCs removal methods using a photocatalyst or ozone, VOCs are oxidized in the gas phase. Therefore, incompletely oxidized intermediates, which may have adverse effects on health, are likely to contaminate the treated air. On the other hand, in the VOCs removal method developed in this study, because the VOCs are oxidized in the liquid phase by the photo-Fenton reaction, any incompletely oxidized intermediates produced are confined to the liquid phase. As a result, the contamination of the treated air by these harmful intermediates can be prevented. Using a semi-batch process, it was found that the removal efficiency for toluene in a one-pass test (residence time of 17s) was 61%, for an inlet toluene gas concentration of 930 ppbv, an initial iron ion concentration of 20 mg L(-1), and an initial hydrogen peroxide concentration of 630 mg L(-1). The removal efficiency was almost constant as long as H(2)O(2) was present in the solution. Proton transfer reaction mass spectrometry analysis confirmed the absence of any incompletely oxidized intermediates in the treated air"
Keywords:Air Pollutants/*analysis/chemistry Air Pollution/*prevention & control Environmental Restoration and Remediation/methods Hydrogen Peroxide/chemistry Iron/chemistry Oxidation-Reduction Toluene/*analysis/chemistry Volatile Organic Compounds/*analysis/chemis;
Notes:"MedlineTokumura, Masahiro Wada, Yuko Usami, Yuri Yamaki, Takako Mizukoshi, Atsushi Noguchi, Miyuki Yanagisawa, Yukio eng England 2012/08/09 Chemosphere. 2012 Nov; 89(10):1238-42. doi: 10.1016/j.chemosphere.2012.07.018. Epub 2012 Aug 4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024