Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractField study of visitors' behavior in incense burning and its induced air pollution assessment and treatment    Next AbstractDiffusive transport in Stokeslet flow and its application to plankton ecology »

Spectrochim Acta A Mol Biomol Spectrosc


Title:"Measurement of acrolein and 1,3-butadiene in a single puff of cigarette smoke using lead-salt tunable diode laser infrared spectroscopy"
Author(s):Thweatt WD; Harward CN; Parrish ME;
Address:"Philip Morris USA Post Graduate Research Program, 4201 Commerce Road, Richmond, VA 23234, USA"
Journal Title:Spectrochim Acta A Mol Biomol Spectrosc
Year:2007
Volume:20061025
Issue:1
Page Number:16 - 24
DOI: 10.1016/j.saa.2006.10.034
ISSN/ISBN:1386-1425 (Print) 1386-1425 (Linking)
Abstract:"Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.8 cm(-1) and 891.0 cm(-1) respectively for the simultaneous measurement of acrolein and 1,3-butadiene, respectively, in each puff of mainstream cigarette smoke in real time. The dual TDL system uses a 3.1l volume, 100 m astigmatic multiple pass absorption gas cell. Quantitation is based on a spectral fit that uses previously determined infrared molecular line parameters generated in our laboratory, including line positions, line strengths and nitrogen-broadened half-widths for these species. Since acrolein and ethylene absorption lines overlap and 1,3-butadiene, ethylene and propylene absorption lines overlap, the per puff deliveries of ethylene and propylene were determined since their overlapping absorption lines must be taken into account by the spectral fit. The acrolein and 1,3-butadiene total cigarette deliveries for the 1R5F Kentucky Reference cigarette were in agreement with the HPLC and GC/MS methods, respectively. The limit of detection (LOD) for 1,3-butadiene and acrolein was 4 ng/puff and 24 ng/puff, respectively, which is more than adequate to determine at which puff they break through the carbon filter. The retention and breakthrough behavior for the two primary smoke constituents depend on the cigarette design and characteristics of the carbon filter being evaluated"
Keywords:"Acrolein/*analysis Butadienes/*analysis Humans Lasers Smoke/*analysis *Smoking Spectroscopy, Fourier Transform Infrared/methods;"
Notes:"MedlineThweatt, W Dave Harward, Charles N Sr Parrish, Milton E eng Research Support, Non-U.S. Gov't Review England 2006/12/05 Spectrochim Acta A Mol Biomol Spectrosc. 2007 May; 67(1):16-24. doi: 10.1016/j.saa.2006.10.034. Epub 2006 Oct 25"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024