Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractHerbivory and pollination impact on the evolution of herbivore-induced plasticity in defense and floral traits    Next AbstractFunctionalization of metal organic frameworks by [BMIM][CH(3)COO] ionic liquid for toluene capture »

Sci Total Environ


Title:Assessment of air passive sampling uptakes for volatile organic compounds using VERAM devices
Author(s):Ramos TD; de la Guardia M; Pastor A; Esteve-Turrillas FA;
Address:"Department of Analytical Chemistry, University of Valencia, Jeroni Munoz Building, 50th Dr. Moliner St., 46100 Burjassot, Spain; Departamento de Quimica Analitica, Universidade Federal Fluminense, Outeiro de Sao Joao Batista s/n, Niteroi, RJ 24020-141, Brazil. Department of Analytical Chemistry, University of Valencia, Jeroni Munoz Building, 50th Dr. Moliner St., 46100 Burjassot, Spain. Department of Analytical Chemistry, University of Valencia, Jeroni Munoz Building, 50th Dr. Moliner St., 46100 Burjassot, Spain. Electronic address: francesc.a.esteve@uv.es"
Journal Title:Sci Total Environ
Year:2018
Volume:20171129
Issue:
Page Number:1014 - 1021
DOI: 10.1016/j.scitotenv.2017.11.173
ISSN/ISBN:1879-1026 (Electronic) 0048-9697 (Linking)
Abstract:"A calibration chamber has been designed and employed for the simple and easy determination of uptake sampling rate (R(S)) of volatile organic compounds (VOCs) from air using passive samplers. A flow of clean air was continuously spiked, at a constant VOC concentration, by the microinjection of a standard solution by means of a T-type tube. The developed system allowed the complete evaporation at room temperature of the standard solution in acetone and the air concentration of VOCs was easily controlled by the regulation of the clean air flow, the standard solution concentration and its flow. Active sampling was employed for monitoring the true concentration of the evaluated compounds inside the calibration chamber, using Tenax-filled desorption tubes and a low flow personal air sampling pump. Versatile, easy and rapid atmospheric monitor (VERAM) devices were employed for the passive sampling of benzene, toluene, ethylbenzene, xylenes, alpha-pinene, camphene, myrcene, p-cymene, and limonene from air. The R(S) values obtained for the passive sampling of VOCs, using the developed calibration chamber, were in the range of 1.3-16.0m(3)day(-1) in accordance to previous calibration studies performed for VERAM samplers. The developed calibration chamber provided a continuous flow with a constant concentration of the evaluated compounds that allowed the simultaneous deployment of several samplers for a rapid establishment of R(S) for a passive sampler type and the easy comparison between different devices"
Keywords:Air sampling Btex Passive sampler Sampling rate Terpene Veram;
Notes:"PubMed-not-MEDLINERamos, Thalita Dallapicula de la Guardia, Miguel Pastor, Agustin Esteve-Turrillas, Francesc A eng Netherlands 2018/05/08 Sci Total Environ. 2018 Apr 1; 619-620:1014-1021. doi: 10.1016/j.scitotenv.2017.11.173. Epub 2017 Nov 29"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024