Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffect of age on the profile of alkanes in normal human breath    Next AbstractDetection of lung cancer with volatile markers in the breath »

Heart Dis


Title:Breath markers of oxidative stress in patients with unstable angina
Author(s):Phillips M; Cataneo RN; Greenberg J; Grodman R; Salazar M;
Address:"Menssana Research Inc, Fort Lee, NJ 07024, USA. menssana@bellatlantic.net"
Journal Title:Heart Dis
Year:2003
Volume:5
Issue:2
Page Number:95 - 99
DOI: 10.1097/01.hdx.0000061701.99611.e8
ISSN/ISBN:1521-737X (Print) 1521-737X (Linking)
Abstract:"Cardiac chest pain is accompanied by oxidative stress, which generates alkanes and other volatile organic compounds (VOCs). These VOCs are excreted in the breath and could potentially provide a rational diagnostic marker of disease. The breath methylated alkane contour (BMAC), a 3-dimensional surface plot of C4-C20 alkanes and monomethylated alkanes, provides a comprehensive set of markers of oxidative stress. In this pilot study, we compared BMACs in patients with unstable angina pectoris and in healthy volunteers. Breath VOCs were analyzed in 30 patients with unstable angina confirmed by coronary angiography and in 38 age-matched healthy volunteers with no known history of heart disease (mean age +/- SD, 62.7 +/- 12.3 years and 62.5 +/- 10.0, not significant). BMACs in both groups were compared to identify the combination of VOCs that provided the best discrimination between the 2 groups. Forward stepwise entry discriminant analysis selected 8 VOCs to construct a predictive model that correctly classified unstable angina patients with sensitivity of 90% (27 of 30) and specificity of 73.7% (28 of 38). On cross-validation, sensitivity was 83.3% (25 of 30) and specificity was 71.1% (27 of 38). We conclude that the breath test distinguished between patients with unstable angina and healthy control subjects"
Keywords:"Alkanes/*analysis Angina, Unstable/diagnosis/*metabolism Biomarkers/analysis *Breath Tests Case-Control Studies Discriminant Analysis Humans Methylation Methyltransferases/metabolism Middle Aged Models, Statistical Oxidative Stress/*physiology Pilot Proje;"
Notes:"MedlinePhillips, Michael Cataneo, Renee N Greenberg, Joel Grodman, Richard Salazar, Manuel eng 2003/04/26 Heart Dis. 2003 Mar-Apr; 5(2):95-9. doi: 10.1097/01.hdx.0000061701.99611.e8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024