Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAmbient level volatile organic compound (VOC) monitoring using solid adsorbents--recent US EPA studies    Next AbstractComparison of 24 h averaged VOC monitoring results for residential indoor and outdoor air using Carbopack X-filled diffusive samplers and active sampling--a pilot study »

J Environ Monit


Title:24 h diffusive sampling of toxic VOCs in air onto Carbopack X solid adsorbent followed by thermal desorption/GC/MS analysis-laboratory studies
Author(s):McClenny WA; Oliver KD; Jacumin HH; Daughtrey EH; Whitaker DA;
Address:"National Exposure Research Laboratory, US Environmental Protection Agency, Research Triangle Park, NC 27711, USA"
Journal Title:J Environ Monit
Year:2005
Volume:20050126
Issue:3
Page Number:248 - 256
DOI: 10.1039/b412213e
ISSN/ISBN:1464-0325 (Print) 1464-0325 (Linking)
Abstract:"Diffusive sampling of a mixture of 42 volatile organic compounds (VOCs) in humidified, purified air onto the solid adsorbent Carbopack X was evaluated under controlled laboratory conditions. The evaluation included variations in sample air temperature, relative humidity and ozone concentration. Linearity of samples with loading was examined both for a constant concentration with time varied up to 24 h and for different concentrations over 24 h. Reverse diffusion and its increase with accumulation of sample were determined for all compounds. Tubes were examined for blank levels, change of blanks with storage time, and variability of blanks. Method detection limits were determined based on seven replicate samples. Based on this evaluation, 27 VOCs were selected for quantitative monitoring in the concentration range from approximately 0.1 to 4 ppbv. Comparison results of active and diffusive samples taken over 24 h and under the same simulated ambient conditions at a constant 2 ppbv were interpreted to estimate the effective diffusive sampling rates (ml min(-1)) and their uncertainties and to calculate the corresponding diffusive uptake rates (ng ppmv(-1) min(-1))"
Keywords:Adsorption Environmental Monitoring/instrumentation/*methods Gas Chromatography-Mass Spectrometry Hot Temperature Organic Chemicals/*analysis Time Factors Volatilization;
Notes:"MedlineMcClenny, William A Oliver, Karen D Jacumin, Henry H Jr Daughtrey, E Hunter Jr Whitaker, Donald A eng Research Support, U.S. Gov't, Non-P.H.S. England 2005/03/01 J Environ Monit. 2005 Mar; 7(3):248-56. doi: 10.1039/b412213e. Epub 2005 Jan 26"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024