Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of Rhizospheric Actinomycete Streptomyces lavendulae SPS-33 and the Inhibitory Effect of its Volatile Organic Compounds against Ceratocystis Fimbriata in Postharvest Sweet Potato (Ipomoea Batatas (L.) Lam.)    Next AbstractMutation of doublesex in Hyphantria cunea results in sex-specific sterility »

J Sep Sci


Title:Layered double hydroxide/poly(vinylpyrrolidone) coated solid phase microextraction Arrow for the determination of volatile organic compounds in water
Author(s):Li X; Lan H; Hartonen K; Jussila M; Wang X; Riekkola ML;
Address:"School of Molecular Science and Engineering, South China University of Technology, Guangzhou, 510640, P. R. China. Department of Chemistry and Institute for Atmospheric and Earth System Research, P.O. Box 55, FI-00014 University of Helsinki, Helsinki, Finland. College of Chemistry, Jilin University, Qianjin Street 2699, Changchun, 130012, P. R. China"
Journal Title:J Sep Sci
Year:2020
Volume:20200624
Issue:16
Page Number:3285 - 3293
DOI: 10.1002/jssc.202000239
ISSN/ISBN:1615-9314 (Electronic) 1615-9306 (Linking)
Abstract:"Today, wide variety of adsorbents have been developed for sample pretreatment to concentrate and separate harmful substances. However, only a few solid phase microextraction Arrow adsorbents are commercially available. In this study, we developed a new solid phase microextraction Arrow coating, in which nanosheets layered double hydroxides and poly(vinylpyrrolidone) were utilized as the extraction phase and poly(vinyl chloride) as the adhesive. This new coating entailed higher extraction capacity for several volatile organic compounds (allyl methyl sulfide, methyl propyl sulfide, 3-pentanone, 2-butanone, and methyl isobutyl ketone) compared to the commercial Carboxen 1000/polydimethylsiloxane coating. Fabrication parameters for the coating were optimized and extraction and desorption conditions were investigated. The validation of the new solid phase microextraction Arrow coating was accomplished using water sample spiked with volatile organic compounds. Under the optimal conditions, the limits of quantification for the five volatile organic compounds by the new solid phase microextraction Arrow coating and developed gas chromatography with mass spectrometry method were in the range of 0.2-4.6 ng/mL. The proposed method was briefly applied for enrichment of volatile organic compounds in sludge"
Keywords:gas chromatography layered double hydroxides poly(vinylpyrrolidone) solid phase microextraction Arrow volatile organic compounds;
Notes:"PubMed-not-MEDLINELi, Xinpei Lan, Hangzhen Hartonen, Kari Jussila, Matti Wang, Xinghua Riekkola, Marja-Liisa eng 201706170136/China Scholarship Council/ 201508330310/China Scholarship Council/ grant no. 307331/Academy of Finland/ Germany 2020/06/09 J Sep Sci. 2020 Aug; 43(16):3285-3293. doi: 10.1002/jssc.202000239. Epub 2020 Jun 24"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024