Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCharacterisation of aroma-active compounds in Guilin Huaqiao white sufu and their influence on umami aftertaste and palatability of umami solution    Next AbstractEnhanced biodegradation of n-hexane by Pseudomonas sp. strain NEE2 »

J Air Waste Manag Assoc


Title:Comparison of the purification performance and microbial community functional diversity in flow-directional-switching and unidirectional-flow biotrickling filters
Author(s):He S; Wang L; Xu J; Yin N;
Address:"School of Environment and Spatial Informatics, China University of Mining and Technology, University Road, Xuzhou, Jiangsu 221116, PR China. hslongrcees@163.com"
Journal Title:J Air Waste Manag Assoc
Year:2012
Volume:62
Issue:10
Page Number:1203 - 1207
DOI: 10.1080/10962247.2012.700900
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"Because of the characteristics of low operating cost and convenient operation, the biotrickling filter is extensively researched and used to treat low concentration waste gas contaminated by volatile organic compounds (VOCs) and other odors. In this paper, two laboratory-scale biotrickling filters were constructed and toluene was selected as the sole carbon source, and the effects of different waste-gas flow configuration patterns on the purification capacity and the microbial community functional diversity of biotrickling filters were evaluated. The results indicated that the flow-directional-switching (FDS) biotrickling filter had better purification performance, and the maximum elimination capacity reached 480 g x m(-3) x hr(-1), which was 17.1% higher than conventional unidirectional-flow (UF) biotrickling filter. Comparing the purification capacities of different sections in two biotrickling filters, the maximum toluene elimination capacity of section III in FDS system could reach 542 g x m(-3) x hr(-1), which was 2.8 times as great as that in UF system, which resulted from the difference of elimination capacity in two systems. By analyzing the metabolic activity of two systems by community-level physiological profiling (CLPP) with Biolog (Biolog Inc., Hayward, CA) ECO-plate technique, metabolic activity in three sections of FDS system was higher than that of UF system. The metabolic activity was the highest in section III of FDS system and 46.8% higher than that of UF system. Shannon index and McIntosh index of section III in FDS system were 6.2% and 31.5% higher, respectively, than those of UF system. IMPLICATIONS: The flow-directional-switching (FDS) biotrickling filter had a better purification performance than unidirectional-flow (UF) biotrickling filter at high inlet loadings, because FDS produced a more uniform distribution of biomass and microbial metabolic capacity along the length of the packed bed without diminishing activity and removal capacity in the inlet section"
Keywords:"Air Pollutants/*metabolism Bacteria/metabolism Biodegradation, Environmental Bioreactors/*microbiology Chromatography, Gas Environmental Restoration and Remediation/instrumentation/*methods Filtration/instrumentation/*methods Toluene/*metabolism;"
Notes:"MedlineHe, Shilong Wang, Liping Xu, Jiangcen Yin, Ningning eng Comparative Study Evaluation Study 2012/11/20 J Air Waste Manag Assoc. 2012 Oct; 62(10):1203-7. doi: 10.1080/10962247.2012.700900"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024