Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRemediation characteristics of surfactant-enhanced air sparging (SEAS) technology on volatile organic compounds contaminated soil with low permeability    Next AbstractOlfactory perception and behavioral effects of sex pheromone gland components in Helicoverpa armigera and Helicoverpa assulta »

Guang Pu Xue Yu Guang Pu Fen Xi


Title:[Study on simultaneous analysis of indoor air multi-component VOCs with FTIR]
Author(s):Xu LE; Feng YQ; Chen JQ;
Address:"Institute of Safety and Environment Protection, China Jiliang University, Hangzhou 310018, China"
Journal Title:Guang Pu Xue Yu Guang Pu Fen Xi
Year:2006
Volume:26
Issue:12
Page Number:2197 - 2199
DOI:
ISSN/ISBN:1000-0593 (Print) 1000-0593 (Linking)
Abstract:"Recently, the indoor air pollution, especially the volatile organic compounds (VOCs) is attracting more and more attention. The determination of indoor air organic gases becomes the key issue. In the present paper, a simultaneous quantitative measuring method of indoor air multi-component VOCs was established based on FTIR combined with chemometrics. The 3 200-2 600 cm(-1) and 1 100-600 cm(-1) bands of IR spectrum were used to establish validation model, and excellent coefficients were obtained (r(2) =0. 970, 0. 955 and 0. 946 for benzene, toluene and dimethylbenzene, respectively). The root mean standard error of calibration for benzene, toluene and dimethylbenzene is 0. 074 2, 0. 081 9 and 0. 087 7, respectively. The root mean standard error of prediction is 0. 132, 0. 134 and 0. 033 3, respectively. The error of unknown sample prediction is acceptable. The IR method is effective for simultaneous analysis of indoor air multi-component VOCs. The model established by partial least squares (PLS) is better than that by principal components analysis (PCR)"
Keywords:
Notes:"PubMed-not-MEDLINEXu, Li-eng Feng, Yan-qing Chen, Jian-qi chi English Abstract China 2007/03/17 Guang Pu Xue Yu Guang Pu Fen Xi. 2006 Dec; 26(12):2197-9"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024