Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractThe concentration of volatile organic compounds (VOCs) in pig farm air    Next AbstractDetrimental effects of cement mortar and fly ash mortar on asthma progression »

Ann Agric Environ Med


Title:Occupational exposure level of pig facility workers to chemical and biological pollutants
Author(s):Chmielowiec-Korzeniowska A; Tymczyna L; Pyrz M; Trawinska B; Abramczyk K; Dobrowolska M;
Address:"University of Life Sciences in Lublin. anna.korzeniowska@up.lublin.pl. University of Life Sciences in Lublin. leszek.tymczyna@up.lublin.pl. University of Life Sciences in Lublin. magdalena.pyrz@up.lublin.pl. University of Life Sciences in Lublin. beata.trawinska@up.lublin.pl. Institute of Soil Science and Plant Cultivation - State Research Institute, Pulawy. karol.abramczyk100@o2.pl. University of Life Sciences in Lublin. magdezja@up.lublin.pl"
Journal Title:Ann Agric Environ Med
Year:2018
Volume:20171106
Issue:2
Page Number:262 - 267
DOI: 10.26444/aaem/78479
ISSN/ISBN:1898-2263 (Electronic) 1232-1966 (Linking)
Abstract:"OBJECTIVE: The aim of the study was to assess the impact of a fattening season on the level of airborne chemical and microbial pollutants in the pig fattening house. MATERIAL AND METHODS: Evaluation of the air composition as well as the microbiological air quality were made during 2 series, i.e. in the summer and winter period of fattening. Airborne gaseous pollutants were analyzed by gas (organic compounds) and liquid (inorganic compounds) chromatography methods. Air microbial contamination was determined in compliance with the Polish Standard PN-EN 13098:2007. RESULTS: The air/gas composition in the pig unit showed that irrespective of the fattening season, the level of determined pollutants - especially ammonia, volatile organic compounds (VOCs), including methanethiol and total dust - could have an adverse effect on the health of swine facility workers. The investigated pig building was found to be a source of chemical pollutants as well as biological agents. The total bacterial count in 1 m3 of air was 3.6x106 and 4.6x106 cfu, during the winter and summer periods of fattening, respectively. Gram-positive cocci predominated in both seasons. In the winter, fungi of the Trichoderma genus were represented equally often. In the summer period, up to 90% of the isolated fungus was Aspergillus spp. CONCLUSIONS: Workers engaged in swine rearing and production are occupationally exposed not only to a high concentration of microbial contamination, but also to irritating and odorogenous volatile compounds. Thus, activities directed at the promotion of health prevention strategies, as well as effective guidelines for safe and hygienic animal housing, should be implemented"
Keywords:"Adult Agricultural Workers' Diseases/etiology *Air Microbiology Air Pollutants, Occupational/adverse effects/*chemistry *Animal Husbandry Animals Environmental Pollutants/adverse effects/*chemistry Farmers Female Housing, Animal Humans Male Occupational E;"
Notes:"MedlineChmielowiec-Korzeniowska, Anna Tymczyna, Leszek Pyrz, Magdalena Trawinska, Beata Abramczyk, Karol Dobrowolska, Magdalena eng Poland 2018/06/26 Ann Agric Environ Med. 2018 Jun 20; 25(2):262-267. doi: 10.26444/aaem/78479. Epub 2017 Nov 6"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024