Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractRegulation of bacteriocin production in Lactobacillus plantarum depends on a conserved promoter arrangement with consensus binding sequence    Next AbstractTranspiration directly regulates the emissions of water-soluble short-chained OVOCs »

J Environ Monit


Title:Quantification of re-evaporated mass from loaded fibre-mist eliminators
Author(s):Riss B; Wahlmuller E; Hoflinger W;
Address:"PROFACTOR GmbH, Wehrgrabengasse 1-5, A-4400 Steyr, Austria. briss@pr-steyr.ac.at"
Journal Title:J Environ Monit
Year:1999
Volume:1
Issue:4
Page Number:373 - 377
DOI: 10.1039/a902767j
ISSN/ISBN:1464-0325 (Print) 1464-0325 (Linking)
Abstract:"Airborne lubricant emissions are a serious health hazard for employees in the metal working industry. The basic components of lubricants are oils and additives for adapting the properties to achieve the process demands. The oils used in lubricants are either mineral, synthetic or of biological origin. The lubricants are used as water-emulsions and also as straight oils. Extreme process conditions cause considerable amounts of aerosol and vapour emissions of lubricants into the working environment. Fibre filters are used in industrial demisters for pollution control and also for sampling purposes. Re-evaporation of separated lubricants from loaded fibre filters causes increased vapour emissions. Quantification of lubricant vapour emission was the subject of this research. An apparatus and an appropriate procedure for measuring the dynamic behaviour of evaporative losses from fibre filters were developed. The test piece of a loaded fibre filter was fixed in a sampling probe according to VDI 2066. The vapour concentration of organic compounds in downstream air was measured in real-time by using a photo-ionisation detector (PID). The PID was checked by sampling the vapour on an oleophilic adsorbent resin, solvent extraction and quantitative IR analysis and also gravimetrically. The two basic processes of filtering volatile aerosols are, on the one hand, collecting droplets on the fibres and, on the other hand, the evaporation of collected liquid. These two processes had to be separated in order to measure the increase of the vapour concentration caused by the tested fibre filter. The experiments were carried out using pure dodecane and hexadecane in order to avoid difficulties due to the unknown chemical composition of lubricant vapour. The variation of the air flow and the initial liquid mass on the filter covered the relevant range for industrial fibre demisters and for sampling methods based on collecting aerosols on fibre filters. It was found that the downstream air was saturated with lubricant vapour for a wide range of filter loads and filtration velocities. From the results obtained it can be concluded that loaded industrial filter systems emit air with saturation vapour concentration throughout their operation. Hence, vapour emissions can be estimated easily if the saturation vapour pressure and the mean relative molecular mass are known. Moreover, results obtained from measurements of filters with low loads confirm that the phase transition from liquid to vapour is influenced by the identified process parameters. This is relevant for measurement methods using fibre filters for sampling volatile aerosols. A semi-empirical model to estimate the evaporative losses for low loadings is proposed. However, further research is necessary to determine the full range of parameters that are relevant for evaporative losses from filters loaded with low masses of aerosols"
Keywords:"Air Pollution, Indoor/*analysis Environmental Monitoring/*instrumentation Filtration Humans Hydrocarbons/*analysis Lubrication Models, Theoretical *Occupational Exposure Volatilization;"
Notes:"MedlineRiss, B Wahlmuller, E Hoflinger, W eng England 2001/09/01 J Environ Monit. 1999 Aug; 1(4):373-7. doi: 10.1039/a902767j"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024