Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOptimisation of a simple and reliable method based on headspace solid-phase microextraction for the determination of volatile phenols in beer    Next AbstractRecognition of volatile compounds as markers in geographical discrimination of Spanish extra virgin olive oils by chemometric analysis of non-specific chromatography volatile profiles »

Anal Bioanal Chem


Title:Prediction of total and volatile acidity in red wines by Fourier-transform mid-infrared spectroscopy and iterative predictor weighting
Author(s):Pizarro C; Gonzalez-Saiz JM; Esteban-Diez I; Orio P;
Address:"Department of Chemistry, University of La Rioja, C/Madre de Dios 51, 26006 Logrono, La Rioja, Spain. consuelo.pizarro@unirioja.es"
Journal Title:Anal Bioanal Chem
Year:2011
Volume:20101103
Issue:6
Page Number:2061 - 2072
DOI: 10.1007/s00216-010-4356-6
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"Fourier-transform mid-infrared (FT-MIR) spectroscopy, combined with partial least-squares (PLS) regression and IPW as feature selection method, was used to develop reduced-spectrum calibration models based on a few IR bands to provide near-real-time predictions of two key parameters for the characterization of finished red wines, which are essential from a quality assurance standpoint: total and volatile acidity. Separate PLS calibration models, correlating IR data (only considering those regions showing a high signal to noise ratio) with each response studied, were developed. Wavenumber selection was also performed applying IPW-PLS to take into account only significant predictors, in an attempt to improve the quality of the final models constructed. Using both PLS and IPW-PLS regression, prediction of the two responses modelled was performed with very high reliability, with RMSECV and RMSEP values on the order of 1% (comparable in terms of accuracy to the results provided by the respective reference analysis methods). An important advantage derived from the application of the IPW-PLS method had to do with the low number of original variables needed for modelling both total acidity (22 significant wavenumbers) and volatile acidity (only 11 selected predictor variables), in such a way that variable selection contributed to enhance the stability and parsimony properties of the final calibration models. The high quality of the calibration models proposed encourages the feasibility of implementing them as a fast and reliable tool in routine analysis for the determination of critical parameters for wine quality"
Keywords:"Acids/*analysis Least-Squares Analysis Quality Control Spectroscopy, Fourier Transform Infrared/*methods/statistics & numerical data Volatile Organic Compounds/*analysis Wine/*analysis/standards;"
Notes:"MedlinePizarro, C Gonzalez-Saiz, J M Esteban-Diez, I Orio, P eng Evaluation Study Research Support, Non-U.S. Gov't Germany 2010/11/03 Anal Bioanal Chem. 2011 Feb; 399(6):2061-72. doi: 10.1007/s00216-010-4356-6. Epub 2010 Nov 3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-07-2024