Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractThe potential of NO(+) and O(2) (+*) in switchable reagent ion proton transfer reaction time-of-flight mass spectrometry    Next AbstractToward Smart Online Coffee Roasting Process Control: Feasibility of Real-Time Prediction of Coffee Roast Degree and Brew Antioxidant Capacity by Single-Photon Ionization Mass Spectrometric Monitoring of Roast Gases »

Environ Sci Process Impacts


Title:Passive diffusive flux chambers - a new method to quantify vapour intrusion into indoor air
Author(s):Heggie AC; Stavropoulos B;
Address:"WSP Australia, Sydney, NSW 2000, Australia. adrian.heggie@wsp.com. Leeder Consulting, QLD, Australia. bill.stavropoulos@sgs.com"
Journal Title:Environ Sci Process Impacts
Year:2018
Volume:20180206
Issue:3
Page Number:523 - 530
DOI: 10.1039/c7em00569e
ISSN/ISBN:2050-7895 (Electronic) 2050-7887 (Linking)
Abstract:"A new instrumental method (a passive flux chamber) to quantify emission rates of volatile organic compounds (VOCs) from natural ground surfaces and floors or pavements was developed and tested against the traditional emission isolation flux chamber (the dynamic flux chamber). Dynamic flux chambers have been used for some decades to measure diffusive mass flux of VOCs at contaminated sites thereby providing quantitative estimates of the contribution of contaminant vapour fluxes to indoor air concentrations for human health risk assessments. The new method described here measures diffusive mass flux from surfaces utilising a high uptake rate passive absorptive sampling tube placed within a chamber to capture the mass molecular flux. The passive flux chamber was developed to provide a technically simpler and more cost effective means of quantifying vapour intrusion rates into buildings where the dominant pathway for VOC intrusion through floors is molecular diffusion rather than pressure driven advective flows through floor gaps and cracks. The passive flux chamber operation is based on the principal of molecular diffusion and the random movement of molecules in the gaseous phase. The efficiency of the passive chamber in capturing the total mass flux was tested by measuring comparative concentrations in adjacent identical chambers, one fitted with and the other without an absorptive sampling tube. For chambers fitted with sampling tubes the internal chamber concentrations of VOCs were on average 85% lower than for co-located chambers not fitted with the absorption tubes, demonstrating a high rate of capture of VOC flux into the chamber and a close and satisfactory approximation of mass flux. Eighteen field comparisons of surface fluxes measured by the passive and dynamic flux chamber methods showed that on average the passive chambers produced flux rates a factor of two greater than the dynamic flux chambers"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis Diffusion Environmental Monitoring/instrumentation/*methods Equipment Design Floors and Floorcoverings Gases/analysis Humans Steam/*analysis Volatile Organic Compounds/*analysis;"
Notes:"MedlineHeggie, Adrian C Stavropoulos, Bill eng England 2018/02/07 Environ Sci Process Impacts. 2018 Mar 1; 20(3):523-530. doi: 10.1039/c7em00569e. Epub 2018 Feb 6"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024