Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPopulation Dynamics of Six Major Insect Pests During Multiple Crop Growing Seasons in Northwestern New Mexico    Next AbstractOn-Line Sorbentless Cryogenic Needle Trap and GC-FID Method for the Extraction and Analysis of Trace Volatile Organic Compounds from Soil Samples »

J Chromatogr Sci


Title:Ultrasonic assisted SPME coupled with GC and GC-MS using pencil lead as a fiber for monitoring the organic volatile impurities of ceftazidime
Author(s):Djozan D; Jouyban A; Norouzi J;
Address:"Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. djozan@tabrizu.ac.ir"
Journal Title:J Chromatogr Sci
Year:2008
Volume:46
Issue:8
Page Number:680 - 685
DOI: 10.1093/chromsci/46.8.680
ISSN/ISBN:0021-9665 (Print) 0021-9665 (Linking)
Abstract:"A simple, rapid, non-destructive, and in-situ method for the isolation and sampling of organic volatile impurities in Ceftazidime is developed using solid-phase microextraction (SPME). For the monitoring of the extracted compounds, gas chromatography (GC) and GC-mass spectrometry analyses are used. The effective factors such as nature of the fiber, SPME mode, extraction temperature, and ultrasonic assistance have been investigated and detailed here. Qualification studies reveal the existence of pyridine (as a degradation product of ceftazidime) and the residual solvents; acetone, methylene-chloride, and diethylamine are the main impurities in the studied pharmaceutical. External standard method is used for quantitative analysis. The % relative standard deviation values are below 10%, and the limits of detection for the detected solvents are 1.06, 0.98, 0.83, and 0.51 ppm, respectively. The proposed method is both accurate and linear and could be used in quality control of ceftazidime and also its stability investigations"
Keywords:"Anti-Bacterial Agents/*chemistry Ceftazidime/*chemistry Chromatography, Gas/*methods Gas Chromatography-Mass Spectrometry/*methods *Graphite Reproducibility of Results Sensitivity and Specificity *Ultrasonics Volatilization;"
Notes:"MedlineDjozan, Djavanshir Jouyban, Abolghasem Norouzi, Jamal eng Research Support, Non-U.S. Gov't 2008/09/18 J Chromatogr Sci. 2008 Sep; 46(8):680-5. doi: 10.1093/chromsci/46.8.680"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024