« Previous AbstractRapid Hydrogen Peroxide release from the coral Stylophora pistillata during feeding and in response to chemical and physical stimuli    Next AbstractVolatile Compounds Produced by Cyanobacteria Isolated from Mangrove Environment »

J Pharm Biomed Anal


Title:Stir bar sorptive extraction combined with GC-MS/MS for determination of low level leachable components from implantable medical devices
Author(s):Armstrong BL; Senyurt AF; Narayan V; Wang X; Alquier L; Vas G;
Address:"Product and Process Scientific Solutions, Johnson & Johnson L.L.C., 1000 Route 202 South, PO Box 300, Raritan, NJ 08869, USA"
Journal Title:J Pharm Biomed Anal
Year:2013
Volume:20121022
Issue:
Page Number:162 - 170
DOI: 10.1016/j.jpba.2012.10.019
ISSN/ISBN:1873-264X (Electronic) 0731-7085 (Linking)
Abstract:"Identification and determination of leachable components are essential for the safety assessment of implantable medical devices. The safety concern threshold (SCT) for leachable components is 0.15 mug/day for genotoxic or carcinogenic compounds and 1.5 mug/day for others. Regulatory agencies require extraction of a whole medical device using an extraction media that simulates in vitro conditions. Large-sized medical devices therefore require large volumes of aqueous media, leading to extracts of very low concentrations of the targeted analytes. Analysis of these dilute solutions is often challenging, and pre-concentration steps are time consuming and can cause significant sample loss. Stir bar sorptive extraction (SBSE) has proven to be a very useful sample preparation technique that is simple and uses no (or minimal (<1 ml)) aqueous or organic solvents. When combined with a highly selective and sensitive GC-MS/MS analysis, volatile and semi-volatile leachable components can be determined at levels below the SCT of 150 ng/device. An SBSE-GC-MS/MS method using multiple reaction monitoring detection was validated for determination of antioxidant related leachable breakdown products from orthopedic knee-inserts made from ultra high molecular weight polyethylene"
Keywords:"Chemical Fractionation/methods Chemistry, Pharmaceutical/methods/standards Gas Chromatography-Mass Spectrometry/*methods/standards *Knee Prosthesis/standards Molecular Weight Polyethylene/analysis/chemistry Reproducibility of Results Tandem Mass Spectrome;"
Notes:"MedlineArmstrong, Barbara L Senyurt, Askim F Narayan, Venkat Wang, Xiande Alquier, Lori Vas, Gyorgy eng England 2012/12/19 J Pharm Biomed Anal. 2013 Feb 23; 74:162-70. doi: 10.1016/j.jpba.2012.10.019. Epub 2012 Oct 22"

 