Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffects of lard on the formation of volatiles from the Maillard reaction of cysteine with xylose    Next AbstractIntegrating multiple analytical platforms and chemometrics for comprehensive metabolic profiling: application to meat spoilage detection »

J Biomed Nanotechnol


Title:Detection and identification of breast cancer volatile organic compounds biomarkers using highly-sensitive single nanowire array on a chip
Author(s):Xu Y; Lee H; Hu Y; Huang J; Kim S; Yun M;
Address:"Department of Electrical and Computer Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15261, USA"
Journal Title:J Biomed Nanotechnol
Year:2013
Volume:9
Issue:7
Page Number:1164 - 1172
DOI: 10.1166/jbn.2013.1651
ISSN/ISBN:1550-7033 (Print) 1550-7033 (Linking)
Abstract:"A single nanowire array on a chip with different materials of Palladium, Polypyrrole and Zinc Oxide has been fabricated using electrochemical deposition method. The fabricated single nanowire array has been demonstrated for highly sensitive and specific diagnosis of breast cancer by detecting four volatile organic compound biomarkers: Heptanal, Acetophenone, Isopropyl Myristate and 2-Propanol. The demonstrated sensing limits for Heptanal, Acetophenone, Isopropyl Myristate and 2-propanol using individual Palladium, Polypyrrole and Zinc Oxide nanowires were 8.982 ppm, 798 ppb, 134 ppm, and 129.5 ppm, respectively, and the corresponding sensitivities of resistance change were in the range of 0.3%-5% which indicated excellent sensing performance of the single nanowires. The response time for Palladium, Polypyrrole and Zinc Oxide nanowires to achieve maximum conductance change was less than 200 seconds while also illustrating excellent signal repeatability. With the principal component analysis of the resistance change versus time in each detection period of the nanowire array, the smell prints for the four volatile organic compounds biomarkers of Breast Cancer are discriminated in the 3-D plots"
Keywords:"Biomarkers, Tumor/*analysis Biosensing Techniques/instrumentation Breast Neoplasms/*diagnosis/*metabolism Breath Tests/*instrumentation Conductometry/*instrumentation Equipment Design Equipment Failure Analysis Female Humans Microarray Analysis/instrument;"
Notes:"MedlineXu, Yiwen Lee, Hyunjoong Hu, Yushi Huang, Jiyong Kim, Suhwan Yun, Minhee eng 1R21EB008825/EB/NIBIB NIH HHS/ Research Support, N.I.H., Extramural Research Support, U.S. Gov't, Non-P.H.S. 2013/08/06 J Biomed Nanotechnol. 2013 Jul; 9(7):1164-72. doi: 10.1166/jbn.2013.1651"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024