Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExposure of passerine birds to brodifacoum during management of Norway rats on farms    Next AbstractExhaled-breath Testing for Prostate Cancer Based on Volatile Organic Compound Profiling Using an Electronic Nose Device (Aeonose): A Preliminary Report »

Pharmaceuticals (Basel)


Title:Analytical Quality by Design: Achieving Robustness of an LC-CAD Method for the Analysis of Non-Volatile Fatty Acids
Author(s):Walther R; Krmar J; Leistner A; Svrkota B; Otasevic B; Malenovic A; Holzgrabe U; Protic A;
Address:"Institute for Pharmacy and Food Chemistry, University of Wurzburg, Am Hubland, 97074 Wurzburg, Germany. Department of Drug Analysis, Faculty of Pharmacy, University of Belgrade, Vojvode Stepe 450, 11 221 Belgrade, Serbia"
Journal Title:Pharmaceuticals (Basel)
Year:2023
Volume:20230323
Issue:4
Page Number: -
DOI: 10.3390/ph16040478
ISSN/ISBN:1424-8247 (Print) 1424-8247 (Electronic) 1424-8247 (Linking)
Abstract:"An alternative to the time-consuming and error-prone pharmacopoeial gas chromatography method for the analysis of fatty acids (FAs) is urgently needed. The objective was therefore to propose a robust liquid chromatography method with charged aerosol detection for the analysis of polysorbate 80 (PS80) and magnesium stearate. FAs with different numbers of carbon atoms in the chain necessitated the use of a gradient method with a Hypersil Gold C(18) column and acetonitrile as organic modifier. The risk-based Analytical Quality by Design approach was applied to define the Method Operable Design Region (MODR). Formic acid concentration, initial and final percentages of acetonitrile, gradient elution time, column temperature, and mobile phase flow rate were identified as critical method parameters (CMPs). The initial and final percentages of acetonitrile were fixed while the remaining CMPs were fine-tuned using response surface methodology. Critical method attributes included the baseline separation of adjacent peaks (alpha-linolenic and myristic acid, and oleic and petroselinic acid) and the retention factor of the last compound eluted, stearic acid. The MODR was calculated by Monte Carlo simulations with a probability equal or greater than 90%. Finally, the column temperature was set at 33 degrees C, the flow rate was 0.575 mL/min, and acetonitrile linearly increased from 70 to 80% (v/v) within 14.2 min"
Keywords:Analytical Quality by Design charged aerosol detector fatty acids magnesium stearate polysorbate 80;
Notes:"PubMed-not-MEDLINEWalther, Rasmus Krmar, Jovana Leistner, Adrian Svrkota, Bojana Otasevic, Biljana Malenovic, Andjelija Holzgrabe, Ulrike Protic, Ana eng Grant Agreement with University of Belgrade-Faculty of Pharmacy No: 451-03-47/2023-01/200161/Ministry of Education and Science of Germany and the Ministry of Education, Science and Technological Development, Republic of Serbia/ Switzerland 2023/04/28 Pharmaceuticals (Basel). 2023 Mar 23; 16(4):478. doi: 10.3390/ph16040478"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024