Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIn vitroand in vivo investigation of metabolic fate of riociguat by HPLC-Q-TOF/MS/MS and in silico evaluation of the metabolites by ADMET predictor()    Next AbstractHormone fatty acid modifications: gram negative bacteria and vertebrates demonstrate common structure and function »

Air Qual Atmos Health


Title:"Ambient levels of volatile organic compounds in the vicinity of petrochemical industrial area of Yokohama, Japan"
Author(s):Tiwari V; Hanai Y; Masunaga S;
Address:"Department of Environment and Information Sciences, Yokohama National University, Yokohama, 240-8501 Japan"
Journal Title:Air Qual Atmos Health
Year:2010
Volume:20091028
Issue:2
Page Number:65 - 75
DOI: 10.1007/s11869-009-0052-0
ISSN/ISBN:1873-9318 (Print) 1873-9326 (Electronic) 1873-9318 (Linking)
Abstract:"Urban ambient air concentrations of 39 aromatic (including benzene, toluene, and xylenes) and aliphatic volatile organic compounds (VOCs) were measured in Yokohama city, Japan. Yokohama city was selected as a case study to assess the amount of VOC released from Industrial area to characterize the ambient air quality with respect to VOC as well as to know the impact of petrochemical storage facilities on local air quality. For this purpose, ambient air samples were collected (from June 2007 to November 2008) at six selected locations which are designated as industrial, residential, or commercial areas. To find out the diurnal variations of VOC, hourly nighttime sampling was carried out for three nights at one of the industrial locations (Shiohama). Samples were analyzed using gas chromatographic system (GC-FID). Results show strong variation between day and nighttime concentrations and among the seasons. Aliphatic fractions were most abundant, suggesting petrochemical storage facilities as the major source of atmospheric hydrocarbons. High concentrations of benzene, toluene, ethyl benzene, and xylene (BTEX) were observed at industrial locations. BTEX showed strong diurnal variation which is attributed to change in meteorology. During our campaign, low ambient VOC concentrations were observed at the residential site"
Keywords:
Notes:"PubMed-not-MEDLINETiwari, Vasu Hanai, Yoshimichi Masunaga, Shigeki eng Netherlands 2010/05/25 Air Qual Atmos Health. 2010 Jun; 3(2):65-75. doi: 10.1007/s11869-009-0052-0. Epub 2009 Oct 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024