Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCorona discharge ion mobility spectrometry with orthogonal acceleration time of flight mass spectrometry for monitoring of volatile organic compounds    Next AbstractMeasurement of personal exposure to volatile organic compounds and particle associated PAH in three UK regions »

Analyst


Title:A corona discharge atmospheric pressure chemical ionization source with selective NO(+) formation and its application for monoaromatic VOC detection
Author(s):Sabo M; Matejcik S;
Address:"Comenius University, Faculty of Mathematics, Physics and Informatics, Department of Experimental Physics, Mlynska dolina F2 842 48 Bratislava, Slovakia. matejcik@fmph.uniba.sk"
Journal Title:Analyst
Year:2013
Volume:138
Issue:22
Page Number:6907 - 6912
DOI: 10.1039/c3an00964e
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"We have developed a new type of corona discharge (CD) for atmospheric pressure chemical ionization (APCI) for application in ion mobility spectrometry (IMS) as well as in mass spectrometry (MS). While the other CD-APCI sources are able to generate H3O(+).(H2O)n as the major reactant ions in N2 or in zero air, the present CD-APCI source has the ability to generate up to 84% NO(+).(H2O)n reactant ions in zero air. The change of the working gas from zero air to N2 allows us to change the major reactant ions from NO(+).(H2O)n to H3O(+).(H2O)n. In this paper we present the description of the new CD-APCI and discuss the processes associated with the NO(+) formation. The selective formation of NO(+).(H2O)n reactant ions offers chemical ionization based on these ions which can be of great advantage for some classes of chemicals. We demonstrate here a significant increase in the sensitivity of the IMS-MS instrument for monoaromatic volatile organic compound (VOC) detection upon NO(+).(H2O)n chemical ionization"
Keywords:
Notes:"PubMed-not-MEDLINESabo, Martin Matejcik, Stefan eng England 2013/10/02 Analyst. 2013 Nov 21; 138(22):6907-12. doi: 10.1039/c3an00964e"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024