Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAssessment of air quality in preschool environments (3-5 years old children) with emphasis on elemental composition of PM10 and PM2.5    Next AbstractEnvironmental Particulate Matter Levels during 2017 Large Forest Fires and Megafires in the Center Region of Portugal: A Public Health Concern? »

J Toxicol Environ Health A


Title:Indoor air quality in preschools (3- to 5-year-old children) in the Northeast of Portugal during spring-summer season: pollutants and comfort parameters
Author(s):Oliveira M; Slezakova K; Delerue-Matos C; Pereira MDC; Morais S;
Address:"a REQUIMTE-LAQV, Instituto Superior de Engenharia do Porto, Instituto Politecnico do Porto , Porto , Portugal. b LEPABE, Departamento de Engenharia Quimica , Faculdade de Engenharia, Universidade do Porto , Porto , Portugal"
Journal Title:J Toxicol Environ Health A
Year:2017
Volume:20170601
Issue:13-15
Page Number:740 - 755
DOI: 10.1080/15287394.2017.1286932
ISSN/ISBN:1528-7394 (Print) 0098-4108 (Linking)
Abstract:"Indoor air quality at schools (elementary, primary) has been the subject of many studies; however, there are still relative few data regarding preschool (3- to 5-year-old children) environments. This investigation determined the concentrations of particulate matter (PM)(2.5), total volatile organic compounds (TVOC), formaldehyde, carbon monoxide (CO), and ozone (O(3)) as well as the levels of carbon dioxide (CO(2)), temperature, and relative humidity (RH) in the indoor and outdoor air of two preschools situated in different geographical regions of Portugal. The indoor concentrations of TVOC, CO, O(3), and CO(2) were predominantly higher at the end of school day compared to early morning periods. The TVOC and CO(2) concentrations were higher indoors than outdoors suggesting predominantly an indoor origin. Outdoor air infiltrations were the major contributing source of CO and O(3) to indoor air in both preschools. The concentrations of all pollutants were within the limits defined by national regulations and international organizations, except for TVOC that exceeded 8-12-fold higher than the recommendation of 0.2 mg/m(3) proposed by European Commission. The levels of CO(2) were below the protective guideline of 2250 mg/m(3) (Portuguese legislation); however, the observed ranges exceeded the Portuguese margin of tolerance (2925 mg/m(3)) at the end of school days, indicating the impact of occupancy rates particularly at one of the preschools. Regarding comfort parameters, temperature exerted a significant influence on O(3) concentrations, while RH values were significantly correlated with TVOC levels in indoor air of preschools, particularly during the late afternoon periods"
Keywords:"Air Pollution, Indoor/adverse effects/*analysis Carbon Dioxide/adverse effects/analysis Carbon Monoxide/adverse effects/analysis Child, Preschool Formaldehyde/adverse effects/analysis Humans Humidity Ozone/adverse effects/analysis Particulate Matter/adver;"
Notes:"MedlineOliveira, Marta Slezakova, Klara Delerue-Matos, Cristina Pereira, Maria do Carmo Morais, Simone eng Research Support, Non-U.S. Gov't England 2017/06/02 J Toxicol Environ Health A. 2017; 80(13-15):740-755. doi: 10.1080/15287394.2017.1286932. Epub 2017 Jun 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-07-2024